High flow anesthesia supplies fresh gas flow which approximates the patient’s minute ventilation, which is usually about 3 to 6 litres per minute in a normal adult. Low flow anesthesia supplies fresh gas flow of less than half the patient's minute ventilation of the patient, which is usually less than 3.0 litres per minute in a normal adult.
Bain circuit: respiratory maintenance circuit Laryngoscope: used to view larynx including the vocal cords, the glottis, etc. Endotracheal tube: a tube introduced into the patient's trachea to maintain a patient to ensure that air reaches the lungs for respiration: Laryngeal mask airway (LMA) a less stimulating alternative to an endotracheal ...
The breathing circuit may be open, closed, or semi-closed, depending on whether breathing gas is recycled. A closed or semi-closed circuit will include components which remove carbon dioxide from the exhaled gas and add oxygen before it is delivered for inhalation, so that the mixture remains stable and suitable for supporting life.
The formation of water by the reaction and the moisture from the respiration also act as a solvent for the reaction. Reactions in aqueous phase are generally faster than between a dry gas and a dry solid. Soda lime is commonly used in closed-circuit diving rebreathers and in the anesthesia breathing circuit in anesthesia systems. [8] [9]
General anaesthesia (UK) or general anesthesia (US) is a method of medically inducing loss of consciousness that renders a patient unarousable even with painful stimuli. [5] This effect is achieved by administering either intravenous or inhalational general anaesthetic medications, which often act in combination with an analgesic and ...
[1] [7] One survey of anesthesiologists who practice intravenous regional anesthesia found that 98% used adjuvant benzodiazepines and/or opioids, with benzodiazepines always being given systemically (to the whole body and brain), whereas opioids can be given either systemically or locally (only into the limb being anesthetized). Most providers ...
Re-entry ventricular arrhythmia is a type of paroxysmal tachycardia occurring in the ventricle where the cause of the arrhythmia is due to the electric signal not completing the normal circuit, but rather an alternative circuit looping back upon itself. [1] There develops a self-perpetuating rapid and abnormal activation.
The original tubes were cut from a roll of rubber industrial tubing by his assistant, hence the natural curve of the tube. A curved metal adaptor was designed (Magill oral and nasal connectors) and a 4" black rubber connecting hose to fit to the anesthetic circuit was adapted from an MG car brake hose and named the 'catheter mount' by Magill's theatre technician at Westminster Hospital.