The Maklakoff tonometer was an early example of this method, while the Goldmann tonometer is the most widely used version in current practice. [3] Because the probe makes contact with the cornea, a topical anesthetic, such as proxymetacaine, is introduced on to the surface of the eye in the form of an eye drop. [citation needed]
A patient in front of a tonometer. Intraocular pressure (IOP) is the fluid pressure inside the eye. Tonometry is the method eye care professionals use to determine this. IOP is an important aspect in the evaluation of patients at risk of glaucoma. [1] Most tonometers are calibrated to measure pressure in millimeters of mercury .
The Schiotz tonometer consists of a curved footplate which is placed on the cornea of a supine patient. A weighted plunger attached to the footplate sinks into the cornea. A scale then gives a reading depending on how much the plunger sinks into the cornea, and a conversion table converts the scale reading into IOP measured in mmHg.
Goldmann Applanation Tonometer attached with Slit lamp biomicroscope Goldmann Applanation Tonometer is an instrument that is based on Imbert-Fick law . It is considered to be the gold standard instrument for measurement of Intraocular pressure (IOP).
Intra-ocular lens IOP: Intra-ocular pressure ISNT: Inferior, Superior, Nasal, Temporal rule used to assess optic disc appearance K: Keratometry OS oculus sinister (left eye) LHyperT or LHT: Left hypertropia LHypoT: Left hypotropia LO: Lenticular opacity L/R FD: L/R fixation disparity L/R: L hyperphoria Left ET: Left esotropia LVA: Low vision ...
The Heidelberg Retinal Tomography is a diagnostic procedure used in ophthalmology.The Heidelberg Retina Tomograph (HRT) is an ophthalmological confocal point scanning laser ophthalmoscope [1] for examining the cornea and certain areas of the retina using different diagnostic modules (HRT retina, HRT cornea, HRT glaucoma).
Armand Imbert (1850-1922) and Adolf Fick (1829-1901) both demonstrated, independently of each other, that in ocular tonometry the tension of the wall can be neutralized when the application of the tonometer produces a flat surface instead of a convex one, and the reading of the tonometer (P) then equals (T) the IOP," whence all forces cancel each other.
For eye pressures, a value of 28 hPa (21 mmHg) above atmospheric pressure 1,010 hPa (760 mmHg) is often used, with higher pressures leading to a greater risk. [2] [26] However, some may have high eye pressure for years and never develop damage. [2] Conversely, optic nerve damage may occur with normal pressure, known as normal-tension glaucoma. [27]