enow.com Web Search

  1. Ads

    related to: daikin not blowing hot air in house fan control systems for large

Search results

  1. Results from the WOW.Com Content Network
  2. Thermal destratification - Wikipedia

    en.wikipedia.org/wiki/Thermal_destratification

    Because axial fans are designed to blow air straight down at the floor, they can be used in ceiling and roof structures over 100 ft. tall. Because axial destratification fans can achieve destratification with low CFMs, it is imperative that the air leaving the nozzle achieve an air speed at the floor of between 0.2 and 0.5 m/s.

  3. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. [1] Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be taken (e.g. start the ...

  4. Air handler - Wikipedia

    en.wikipedia.org/wiki/Air_handler

    An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning system. [1] An air handler is usually a large metal box containing a blower , furnace or A/C elements, filter racks or chambers, sound attenuators , and dampers . [ 2 ]

  5. Variable refrigerant flow - Wikipedia

    en.wikipedia.org/wiki/Variable_refrigerant_flow

    Variable refrigerant flow (VRF), also known as variable refrigerant volume (VRV), is an HVAC technology invented by Daikin Industries, Ltd. in 1982. [1] Similar to ductless mini-split systems, VRFs use refrigerant as the primary cooling and heating medium, and are usually less complex than conventional chiller-based systems.

  6. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    The hot air from the register will mix with the cold air coming off the window, cool, and drop to the floor—creating good air circulation. However, the hot air must be pushed from the register with enough force (or "throw") so that it will cross the room and reach the window. If there is too little throw, the hot air will stop moving partway ...

  7. Variable air volume - Wikipedia

    en.wikipedia.org/wiki/Variable_air_volume

    Control of the system's fan capacity is critical in VAV systems. Without proper and rapid flow rate control, the system's ductwork, or its sealing, can easily be damaged by overpressurization. In the cooling mode of operation, as the temperature in the space is satisfied, a VAV box closes to limit the flow of cool air into the space.

  1. Ads

    related to: daikin not blowing hot air in house fan control systems for large