Search results
Results from the WOW.Com Content Network
Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...
Automatic test equipment diagnostics is the part of an ATE test that determines the faulty components. ATE tests perform two basic functions. The first is to test whether or not the Device Under Test is working correctly. The second is when the DUT is not working correctly, to diagnose the reason.
A control loop using a discrete controller. Field signals are flow rate measurement from the sensor, and control output to the valve. A valve positioner ensures correct valve operation. The simplest control systems are based around small discrete controllers with a single control loop each. These are usually panel mounted which allows direct ...
DNP3 - a protocol used to communicate by industrial control and utility SCADA systems; DirectNet – Koyo / Automation Direct proprietary, yet documented PLC interface; EtherCAT; Ethernet Global Data (EGD) – GE Fanuc PLCs (see also SRTP) EtherNet/IP – IP stands for "Industrial Protocol". An implementation of CIP, originally created by ...
These spark plug velocimeter (SPV) sensors can be inserted into the spark plug hole of the combustion chamber of the engine. The sensors can be adjusted to all depth levels of the pistons movement - typically ranging from 0 - 50mm. The magnifying LDV sensors will record the velocity and direction of the movement of gas particles.
Classifying devices as either "sensor" or "actuator" is outdated and simplistic. Many actuators include controller functionality, but also sensor functionality (for instance measuring operating hours, number of switch cycles, current, electrical power consumption, and more).
A remote terminal unit (RTU) is a microprocessor-controlled electronic device that interfaces objects in the physical world to a distributed control system or SCADA (supervisory control and data acquisition) system by transmitting telemetry data to a master system, and by using messages from the master supervisory system to control connected objects. [1]
A diagnostic program (also known as a test mode) is an automatic computer program sequence that determines the operational status within the software, hardware, or any combination thereof in a component, a system, or a network of systems. Diagnostic programs ideally provide the user with guidance regarding any issues or problems found during ...