enow.com Web Search

  1. Ads

    related to: 1 ohm current shunt

Search results

  1. Results from the WOW.Com Content Network
  2. Shunt (electrical) - Wikipedia

    en.wikipedia.org/wiki/Shunt_(electrical)

    Shunts are rated by maximum current and voltage drop at that current. For example, a 500 A, 75 mV shunt would have a resistance of 150 microohm, a maximum allowable current of 500 amps and at that current the voltage drop would be 75 millivolts. By convention, most shunts are designed to drop 50 mV, 75 mV or 100 mV when operating at their full ...

  3. List of resistors - Wikipedia

    en.wikipedia.org/wiki/List_of_resistors

    An ammeter shunt is a special type of current-sensing resistor, having four terminals and a value in milliohms or even micro-ohms. Current-measuring instruments, by themselves, can usually accept only limited currents. To measure high currents, the current passes through the shunt across which the voltage drop is measured and interpreted as ...

  4. Current sensing - Wikipedia

    en.wikipedia.org/wiki/Current_sensing

    The common and simple approach to current sensing is the use of a shunt resistor. That the voltage drop across the shunt is proportional to its current flow, i.e. ohm's law, makes the low resistance current shunt a very popular choice for current measurement system with its low cost and high reliability.

  5. Admittance - Wikipedia

    en.wikipedia.org/wiki/Admittance

    These shunt components can be referenced to the primary or secondary side. For simplified transformer analysis, admittance from shunt elements can be neglected. When shunt components have non-negligible effects on system operation, the shunt admittance must be considered. In the diagram below, all shunt admittances are referred to the primary side.

  6. Kelvin bridge - Wikipedia

    en.wikipedia.org/wiki/Kelvin_bridge

    To overcome this, a second pair of resistors R′ 1 and R′ 2 form a second pair of arms of the bridge (hence 'double bridge') and are connected to the inner potential terminals of R s and R x (identified as P 2 and P′ 2 in the diagram). The detector D is connected between the junction of R 1 and R 2 and the junction of R′ 1 and R′ 2. [2]

  7. Four-terminal sensing - Wikipedia

    en.wikipedia.org/wiki/Four-terminal_sensing

    Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...

  1. Ads

    related to: 1 ohm current shunt