enow.com Web Search

  1. Ads

    related to: underfloor heating not reaching temperature

Search results

  1. Results from the WOW.Com Content Network
  2. Underfloor heating - Wikipedia

    en.wikipedia.org/wiki/Underfloor_heating

    There is a likelihood that underfloor heating may add to offgassing and sick building syndrome in an environment, particularly when the carpet is used as flooring. [citation needed] Electric underfloor heating systems cause low frequency magnetic fields (in the 50–60 Hz range), old 1-wire systems much more so than modern 2-wire systems.

  3. Hypocaust - Wikipedia

    en.wikipedia.org/wiki/Hypocaust

    Hypocaust under the floor in a Roman villa in Vieux-la-Romaine, near Caen, France. A hypocaust (Latin: hypocaustum) is a system of central heating in a building that produces and circulates hot air below the floor of a room, and may also warm the walls with a series of pipes through which the hot air passes.

  4. Hydronic balancing - Wikipedia

    en.wikipedia.org/wiki/Hydronic_balancing

    Avoiding overflows means the pump is not doing unnecessary work which saves energy, reduces operating cost and can reduce the size of the pump required (saving on the initial pump investment). Balancing also saves energy and operating costs by reducing the amount of time between starting a plant and reaching the required indoor climate.

  5. Radiant heating and cooling - Wikipedia

    en.wikipedia.org/wiki/Radiant_heating_and_cooling

    The lower temperatures and large surface area of underfloor heating systems make them ideal heat emitters for air source heat pumps, evenly and effectively radiating the heat energy from the system into rooms within a home. The maximum temperature of the heating surface can vary from 29–35 °C (84–95 °F) depending on the room type.

  6. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    The ground floor with a slab on grade has less temperature rise compared to middle and top floors, and an increase of the supply air temperature causes a decrease in the temperature rise. The temperature rise is not significantly affected by the perimeter zone orientation, the internal heat gain and the window-to-wall ratio. [16]

  7. Central heating - Wikipedia

    en.wikipedia.org/wiki/Central_heating

    In the early medieval Alpine upland, a simpler central heating system where heat travelled through underfloor channels from the furnace room replaced the Roman hypocaust at some places. In Reichenau Abbey a network of interconnected underfloor channels heated the 300 m 2 large assembly room of the monks during the winter months.

  8. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    Hydronics (from Ancient Greek hydro- ' water ') is the use of liquid water or gaseous water or a water solution (usually glycol with water) as a heat-transfer medium in heating and cooling systems. [ 1 ] [ 2 ] The name differentiates such systems from oil and refrigerant systems.

  9. Thermal destratification - Wikipedia

    en.wikipedia.org/wiki/Thermal_destratification

    The study indicates that stratified buildings tend to overheat or overcool based on the temperature at the thermostat, which tends to be lower than the overall heat energy present in the room. The study also showed that energy waste due to stratification was present at ceiling heights ranging from 20 ft. to 40 ft, and higher ceilings caused ...

  1. Ads

    related to: underfloor heating not reaching temperature