enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Phasor - Wikipedia

    en.wikipedia.org/wiki/Phasor

    Phasor notation (also known as angle notation) is a mathematical notation used in electronics engineering and electrical engineering.A vector whose polar coordinates are magnitude and angle is written . [13] can represent either the vector (⁡, ⁡) or the complex number ⁡ + ⁡ =, according to Euler's formula with =, both of which have magnitudes of 1.

  3. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The field produced by a single-phase winding can provide energy to a motor already rotating, but without auxiliary mechanisms the motor will not accelerate from a stop. A rotating magnetic field of steady amplitude requires that all three phase currents be equal in magnitude, and accurately displaced one-third of a cycle in phase.

  4. Bode plot - Wikipedia

    en.wikipedia.org/wiki/Bode_plot

    The gain A OL is a complex function of frequency, with both magnitude and phase. [note 1] Examination of this relation shows the possibility of infinite gain (interpreted as instability) if the product βA OL = −1 (that is, the magnitude of βA OL is unity and its phase is −180°, the so-called Barkhausen stability criterion). Bode plots ...

  5. Power-flow study - Wikipedia

    en.wikipedia.org/wiki/Power-flow_study

    In power engineering, the power-flow study, or load-flow study, is a numerical analysis of the flow of electric power in an interconnected system. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system, and focuses on various aspects of AC power parameters, such as Voltage, voltage angles, real power and reactive power.

  6. Complex gain - Wikipedia

    en.wikipedia.org/wiki/Complex_gain

    The complex gain G of this circuit is then computed by dividing output by input: G = 2 V j ⋅ 1 V = − 2 j . {\displaystyle G={\frac {2\ V}{j\cdot 1\ V}}=-2j.} This (unitless) complex number incorporates both the magnitude of the change in amplitude (as the absolute value ) and the phase change (as the argument ).

  7. Pole–zero plot - Wikipedia

    en.wikipedia.org/wiki/Pole–zero_plot

    Minimum phase / non minimum phase; A pole-zero plot shows the location in the complex plane of the poles and zeros of the transfer function of a dynamic system, such as a controller, compensator, sensor, equalizer, filter, or communications channel. By convention, the poles of the system are indicated in the plot by an X while the zeros are ...

  8. Phasor measurement unit - Wikipedia

    en.wikipedia.org/wiki/Phasor_measurement_unit

    Using a PMU, it is simple to detect abnormal waveform shapes. A waveform shape described mathematically is called a phasor.. A phasor measurement unit (PMU) is a device used to estimate the magnitude and phase angle of an electrical phasor quantity (such as voltage or current) in the electricity grid using a common time source for synchronization.

  9. Frequency domain - Wikipedia

    en.wikipedia.org/wiki/Frequency_domain

    A complex valued frequency-domain representation consists of both the magnitude and the phase of a set of sinusoids (or other basis waveforms) at the frequency components of the signal. Although it is common to refer to the magnitude portion (the real valued frequency-domain) as the frequency response of a signal, the phase portion is required ...