Phase-to-phase transformer in Britain Primary line on the right toward the front and secondary lines in the back of this single-phase transformer. Both pole-mounted and pad-mounted transformers convert the overhead or underground distribution lines' high 'primary' voltage to the lower 'secondary' or 'utilization' voltage inside the building.
Pad-mount transformers operate on medium-voltage distribution systems, up to about 35 kV. The low-voltage winding matches the customer requirement and may be single-phase or three-phase. Pad-mount transformers are (nearly always) oil-filled units and so must be mounted outdoors only. The core and coils are enclosed in a steel oil-filled tank ...
Pole-mounted single-phase transformer with three-wire center-tapped "split-phase" secondary. On the three secondary terminals, the center tap is grounded with a short strap to the transformer case. A split-phase or single-phase three-wire system is a type of single-phase electric power distribution.
Transformers step down transmission voltages, 35 kV or more, down to primary distribution voltages. These are medium voltage circuits, usually 600–35 000 V. [1] From the transformer, power goes to the busbar that can split the distribution power off in multiple directions. The bus distributes power to distribution lines, which fan out to ...
A pole-mounted three-phase distribution transformer. Low-voltage feeders distributing power to households are placed below the transformer. A low-voltage network or secondary network is a part of electric power distribution which carries electric energy from distribution transformers to electricity meters of end customers.
A mobile substation is a substation on wheels, containing a transformer, breakers and buswork mounted on a self-contained semi-trailer, meant to be pulled by a truck. They are designed to be compact for travel on public roads, and are used for temporary backup in times of natural disaster or war .
Transformer oil is flammable, so oil-filled transformers inside a building are installed in vaults to prevent spread of fire and smoke from a burning transformer. Some transformers were built to use fire-resistant PCBs , but because these compounds persist in the environment and have adverse effects on organisms, their use has been discontinued ...
Parallel operations: All the transformers should have same phase rotation, vector group, tap setting & polarity of the winding. Ground fault Relay: A Dd transformer does not have neutral. To restrict the ground faults in such systems, we may use a zigzag wound transformer to create a neutral along with the ground fault relay.