Search results
Results from the WOW.Com Content Network
Thermal Integrity Profiling (TIP) is a non-destructive testing method used to evaluate the integrity of concrete foundations. It is standardized by ASTM D7949 - Standard Test Methods for Thermal Integrity Profiling of Concrete Deep Foundations. The testing method was first developed in the mid 1990s at the University of South Florida.
The flow table test or slump-flow test is a method to determine consistency of fresh concrete. Flow table test is also used to identify transportable moisture limit of solid bulk cargoes. [ 1 ] It is used primarily for assessing concrete that is too fluid (workable) to be measured using the slump test , because the concrete will not retain its ...
Early diagnosis and analysis of seemingly healthy concrete cover and reinforcement status allows pre-emptive corrosion control measures to reduce unwanted risks to structural safety. [3] Bundesanstalt für Materialforschung und -prüfung (Federal Institute for Materials Research and Testing, Germany) has developed a sensor equipped robotic ...
Epoxy moisture control systems can be applied over concrete with relative humidity levels up to 100%, and there are systems available on the market today that can be applied over concrete that is physically damp. In some cases, with the use of an epoxy moisture control system, floor coverings can be installed just 7 days after the slab is poured.
Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.
The Los Angeles abrasion test (LA abrasion) is the North American standard for testing toughness (resistance to abrasion and degradation [1]) of construction aggregate or gravel and its suitability for road construction. Test methodology and equipment is defined in the ASTM International publications ASTM C131 for particle sizes smaller than 37 ...
Designated as an American National Standard, the Uniform Plumbing Code (UPC) is a model code developed by the International Association of Plumbing and Mechanical Officials to govern the installation and inspection of plumbing systems as a means of promoting the public's health, safety and welfare.
DPC visible between concrete foundation and brickwork. Damp proofing is defined by the American Society for Testing and Materials (ASTM) as a material that resists the passage of water with no hydrostatic pressure. [1] Waterproof is defined by the ASTM as a treatment that resists the passage of water under pressure. [1]