enow.com Web Search

  1. Ads

    related to: bifurcated fan vs axial pump lvad air cooler
  2. shop.advanceautoparts.com has been visited by 100K+ users in the past month

    1097 Cleveland Ave, Columbus, OH · Directions · (380) 210-6243

Search results

  1. Results from the WOW.Com Content Network
  2. Axial fan design - Wikipedia

    en.wikipedia.org/wiki/Axial_fan_design

    The stall zone for the single axial fan and axial fans operated in parallel are shown in the figure. [4] The Figure shows the Stall Prone Areas differently for One fan and Two fans in parallel. [4] The following can be inferred from the graph : For the Fans operated in parallel, the performance is less when compared to the individual fans.

  3. Centrifugal fan - Wikipedia

    en.wikipedia.org/wiki/Centrifugal_fan

    Centrifugal fans displace air radially, changing the direction (typically by 90°) of the airflow. They are sturdy, quiet, reliable, and capable of operating over a wide range of conditions. [3] Centrifugal fans are, like axial fans, constant-volume devices, meaning that, at a constant fan speed, a centrifugal fan moves a relatively constant ...

  4. Affinity laws - Wikipedia

    en.wikipedia.org/wiki/Affinity_laws

    The affinity laws are useful as they allow the prediction of the head discharge characteristic of a pump or fan from a known characteristic measured at a different speed or impeller diameter. The only requirement is that the two pumps or fans are dynamically similar, that is, the ratios of the fluid forced are the same.

  5. Fan (machine) - Wikipedia

    en.wikipedia.org/wiki/Fan_(machine)

    This type of fan is used in a wide variety of applications, ranging from small cooling fans for electronics to the giant fans used in cooling towers. Axial flow fans are applied in air conditioning and industrial process applications. Standard axial flow fans have diameters of 300–400 mm or 1,800–2,000 mm and work under pressures up to 800 ...

  6. Internal combustion engine cooling - Wikipedia

    en.wikipedia.org/wiki/Internal_combustion_engine...

    Comparing air and water, air has vastly lower heat capacity per gram and per volume (4000) and less than a tenth the conductivity, but also much lower viscosity (about 200 times lower: 17.4 × 10 −6 Pa·s for air vs 8.94 × 10 −4 Pa·s for water). Continuing the calculation from two paragraphs above, air cooling needs ten times of the ...

  7. Industrial fan - Wikipedia

    en.wikipedia.org/wiki/Industrial_fan

    This instantaneous blade adjustment capability is an advantage that is possible with axial fans only. Cooling fans - (also referred to as "cooling tower fans") - These are axial fans, typically with large diameters, for low pressures and large volumes of airflow. Applications are in wet mechanical cooling towers, air-cooled steam condensers ...

  8. Axial-flow pump - Wikipedia

    en.wikipedia.org/wiki/Axial-flow_pump

    An axial-flow pump for industrial use. An axial-flow pump, or AFP, is a common type of pump that essentially consists of a propeller (an axial impeller) in a pipe.The propeller can be driven directly by a sealed motor in the pipe or by electric motor or petrol/diesel engines mounted to the pipe from the outside or by a right-angle drive shaft that pierces the pipe.

  9. Variable air volume - Wikipedia

    en.wikipedia.org/wiki/Variable_air_volume

    The fan maintains a constant static pressure in the discharge duct regardless of the position of the VAV box. Therefore, as the box closes, the fan slows down or restricts the amount of air going into the supply duct. As the box opens, the fan speeds up and allows more air flow into the duct, maintaining a constant static pressure. [11]

  1. Ads

    related to: bifurcated fan vs axial pump lvad air cooler