Search results
Results from the WOW.Com Content Network
Absorbance is defined as "the logarithm of the ratio of incident to transmitted radiant power through a sample (excluding the effects on cell walls)". [1] Alternatively, for samples which scatter light, absorbance may be defined as "the negative logarithm of one minus absorptance, as measured on a uniform sample". [2]
The composition of a mixture of N absorbing species can be found by measuring the absorbance at N wavelengths (the values of the molar absorption coefficient for each species at these wavelengths must also be known). The wavelengths chosen are usually the wavelengths of maximum absorption (absorbance maxima) for the individual species.
The most straightforward approach to absorption spectroscopy is to generate radiation with a source, measure a reference spectrum of that radiation with a detector and then re-measure the sample spectrum after placing the material of interest in between the source and detector. The two measured spectra can then be combined to determine the ...
Variable pathlength absorption spectroscopy uses a determined slope to calculate concentration. As stated above this is a product of the molar absorptivity and the concentration. Since the actual absorbance value is taken at many data points at equal intervals, background subtraction is generally unnecessary.
Therefore, measurements at two wavelengths yields two equations in two unknowns and will suffice to determine the amount concentrations c 1 and c 2 as long as the molar attenuation coefficients of the two components, ε 1 and ε 2 are known at both wavelengths. This two system equation can be solved using Cramer's rule.
Table-top spectrophotometer Beckman IR-1 Spectrophotometer, c. 1941 Beckman Model DB Spectrophotometer (a double beam model), 1960 Hand-held spectrophotometer used in graphic industry [1] Spectrophotometry is a branch of electromagnetic spectroscopy concerned with the quantitative measurement of the reflection or transmission properties of a ...
They developed a scheme, subject to the limitations of a two-flux model, to calculate the "scatter corrected absorbance" for a sample. [27] The decadic absorbance of a scattering sample is defined as −log 10 (R+T) or −log 10 (1−A). For a non scattering sample, R = 0, and the expression becomes −log 10 T or log( 1 / T ), which is ...
absorption coefficient is essentially (but not quite always) synonymous with attenuation coefficient; see attenuation coefficient for details; molar absorption coefficient or molar extinction coefficient , also called molar absorptivity , is the attenuation coefficient divided by molarity (and usually multiplied by ln(10), i.e., decadic); see ...