enow.com Web Search

  1. Ads

    related to: toilet shut off valve not working properly

Search results

  1. Results from the WOW.Com Content Network
  2. Low-flow fixtures - Wikipedia

    en.wikipedia.org/wiki/Low-flow_fixtures

    Low-flush toilet (3212351477) Low-flush toilets use significantly less water per flush than older conventional toilets. In the United States, Older conventional toilet models, typically those built before 1982, can use 5 to 7 gallons of water per flush. Toilets from the era of 1982-1993 may use a somewhat smaller 3.5 gpf.

  3. Flushometer - Wikipedia

    en.wikipedia.org/wiki/Flushometer

    Because the water is gradually shut off, slower water at the end of the cycle that will not activate the siphon serves to refill the bowl. The valve cannot be kept open by holding the flush lever in the activated position, wasting water, because this only sends the main cylinder valve all the way up to its topmost shut off position.

  4. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    This gauge uses hoses attached to the various test cocks of the RPZD and checks to be certain that the check valve springs as well as the relief valve spring are not fouled and are working properly. There is a variety of manufacturers of these gauges, but most utilize either a three-valve or a five-valve design to test the RPZD in different ways.

  5. Ballcock - Wikipedia

    en.wikipedia.org/wiki/Ballcock

    The valve is connected to the incoming water supply, and is opened and closed by the lever which has the float mounted on the end. When the water level rises, the float rises with it; once it rises to a pre-set level, the mechanism forces the lever to close the valve and shut off the water flow.

  6. Isolation valve - Wikipedia

    en.wikipedia.org/wiki/Isolation_valve

    Isolation valves must effectively stop the passage of fluids. [4] Gate valves, ball valves and plug valves are generally considered to provide tight and effective shut-off. Globe valves and Butterfly valves may not be tight shut-off due to wear on the plug or the seat, or due to their design, and may not be appropriate to provide effective ...

  7. Atmospheric vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Atmospheric_vacuum_breaker

    If the pressure in the "upstream side" is reduced to atmospheric pressure or below, the poppet valve drops and allows air to enter the system, breaking the siphon. [1] One-Inch Brass Atmospheric Vacuum Breaker mounted on PVC Pipe. These devices, since they work on atmospheric principles, cannot be installed in an enclosure containing air ...

  8. Valve - Wikipedia

    en.wikipedia.org/wiki/Valve

    The shut off butterfly valve for a Francis turbine at Gordon Power Station, Tasmania Ball valve The "seat" is the interior surface of the body which contacts the disc to form a leak-tight seal. In discs that move linearly or swing on a hinge or trunnion, the disc comes into contact with the seat only when the valve is shut.

  9. Tap (valve) - Wikipedia

    en.wikipedia.org/wiki/Tap_(valve)

    Usually, when the handle is in line with the pipe the valve is open, and when the handle is across the pipe it is closed. But it could move in either direction CW or CCW perpendicular to the pipe. S=shut and O=open. A cone valve consists of a shallowly tapering cone in a tight-fitting socket placed across the flow of the fluid.

  1. Ads

    related to: toilet shut off valve not working properly