enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Nyquist stability criterion - Wikipedia

    en.wikipedia.org/wiki/Nyquist_stability_criterion

    A Nyquist plot is a parametric plot of a frequency response used in automatic control and signal processing. The most common use of Nyquist plots is for assessing the stability of a system with feedback. In Cartesian coordinates, the real part of the transfer function is plotted on the X-axis while the imaginary part is plotted on the Y-axis ...

  3. Hall circles - Wikipedia

    en.wikipedia.org/wiki/Hall_circles

    Nichols plot of the transfer function 1/s(1+s)(1+2s) along with the modified M and N circles. To use the Hall circles, a plot of M and N circles is done over the Nyquist plot of the open-loop transfer function. The points of the intersection between these graphics give the corresponding value of the closed-loop transfer function.

  4. Transfer function - Wikipedia

    en.wikipedia.org/wiki/Transfer_function

    The transfer function of a two-port electronic circuit, such as an amplifier, might be a two-dimensional graph of the scalar voltage at the output as a function of the scalar voltage applied to the input; the transfer function of an electromechanical actuator might be the mechanical displacement of the movable arm as a function of electric ...

  5. Nyquist frequency - Wikipedia

    en.wikipedia.org/wiki/Nyquist_frequency

    Early uses of the term Nyquist frequency, such as those cited above, are all consistent with the definition presented in this article.Some later publications, including some respectable textbooks, call twice the signal bandwidth the Nyquist frequency; [6] [7] this is a distinctly minority usage, and the frequency at twice the signal bandwidth is otherwise commonly referred to as the Nyquist rate.

  6. Root locus analysis - Wikipedia

    en.wikipedia.org/wiki/Root_locus_analysis

    The following MATLAB code will plot the root locus of the closed-loop transfer function as varies using the described manual method as well as the rlocus built-in function: % Manual method K_array = ( 0 : 0.1 : 220 ). ' ; % .' is a transpose.

  7. Control theory - Wikipedia

    en.wikipedia.org/wiki/Control_theory

    in the open left half of the complex plane for continuous time, when the Laplace transform is used to obtain the transfer function. inside the unit circle for discrete time, when the Z-transform is used. The difference between the two cases is simply due to the traditional method of plotting continuous time versus discrete time transfer functions.

  8. Transfer function matrix - Wikipedia

    en.wikipedia.org/wiki/Transfer_function_matrix

    In control system theory, and various branches of engineering, a transfer function matrix, or just transfer matrix is a generalisation of the transfer functions of single-input single-output (SISO) systems to multiple-input and multiple-output (MIMO) systems. [1] The matrix relates the outputs of the system to its inputs.

  9. Nonlinear control - Wikipedia

    en.wikipedia.org/wiki/Nonlinear_control

    An example of a nonlinear control system is a thermostat-controlled heating system. A building heating system such as a furnace has a nonlinear response to changes in temperature; it is either "on" or "off", it does not have the fine control in response to temperature differences that a proportional (linear) device would have.