  2. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    For comparison, phenolic foam insulation has a k-value of around 0.018 W/(m⋅K), [23] while wood varies anywhere from 0.15 to 0.75 W/(m⋅K), and steel has a k-value of approximately 50.0 W/(m⋅K). These figures vary from product to product, so the UK and EU have established a 90/90 standard which means that 90% of the product will conform to ...

  3. List of thermal conductivities - Wikipedia

    en.wikipedia.org/wiki/List_of_thermal_conductivities

    Let K 0 is the normal conductivity at one bar (10 5 N/m 2) pressure, K e is its conductivity at special pressure and/or length scale. Let d is a plate distance in meters, P is an air pressure in Pascals (N/m 2 ), T is temperature Kelvin, C is this Lasance constant 7.6 ⋅ 10 −5 m ⋅ K/N and PP is the product P ⋅ d/T .

  4. Thermal conductivity and resistivity - Wikipedia

    en.wikipedia.org/wiki/Thermal_conductivity_and...

    The construction industry makes use of measures such as the R-value (resistance) and the U-value (transmittance or conductance). Although related to the thermal conductivity of a material used in an insulation product or assembly, R- and U-values are measured per unit area, and depend on the specified thickness of the product or assembly. [note 2]

  5. Thermal conductance and resistance - Wikipedia

    en.wikipedia.org/wiki/Thermal_conductance_and...

    The SI unit of absolute thermal resistance is kelvins per watt (K/W) or the equivalent degrees Celsius per watt (°C/W) – the two are the same since the intervals are equal: ΔT = 1 K = 1 °C. The thermal resistance of materials is of great interest to electronic engineers because most electrical components generate heat and need to be cooled.

  6. Rankine scale - Wikipedia

    en.wikipedia.org/wiki/Rankine_scale

    Similar to the Kelvin scale, which was first proposed in 1848, [1] zero on the Rankine scale is absolute zero, but a temperature difference of one Rankine degree (°R or °Ra) is defined as equal to one Fahrenheit degree, rather than the Celsius degree used on the Kelvin scale. In converting from kelvin to degrees Rankine, 1 K = ⁠ 9 / 5 ...

  7. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...

  8. Lankford coefficient - Wikipedia

    en.wikipedia.org/wiki/Lankford_coefficient

    The Lankford coefficient (also called Lankford value, R-value, or plastic strain ratio) [1] is a measure of the plastic anisotropy of a rolled sheet metal. This scalar quantity is used extensively as an indicator of the formability of recrystallized low-carbon steel sheets.

  9. Heat flux measurements of thermal insulation - Wikipedia

    en.wikipedia.org/wiki/Heat_flux_measurements_of...

    In-situ thermal insulation measurement according to ASTM C0141, applying a heat flux sensor to a boiler wall On-site heat flux measurements are often focused on testing the thermal transport properties of for example pipes, tanks, ovens and boilers, by calculating the heat flux q or the apparent thermal conductivity λ {\displaystyle \lambda } .