  2. Dissipation factor - Wikipedia

    en.wikipedia.org/wiki/Dissipation_factor

    The loss tangent is defined by the angle between the capacitor's impedance vector and the negative reactive axis. If the capacitor is used in an AC circuit, the dissipation factor due to the non-ideal capacitor is expressed as the ratio of the resistive power loss in the ESR to the reactive power oscillating in the capacitor, or

  3. Capacitor plague - Wikipedia

    en.wikipedia.org/wiki/Capacitor_plague

    Failed aluminium electrolytic capacitors with open vents in the top of the can, and visible dried electrolyte residue (reddish-brown color) The capacitor plague was a problem related to a higher-than-expected failure rate of non-solid aluminium electrolytic capacitors between 1999 and 2007, especially those from some Taiwanese manufacturers, [1] [2] due to faulty electrolyte composition that ...

  4. Failure of electronic components - Wikipedia

    en.wikipedia.org/wiki/Failure_of_electronic...

    Leads separated from the capacitor by rough handling during storage, assembly or operation, leading to an open failure. The failure can occur invisibly inside the packaging and is measurable. [2] Increase of dissipation factor due to contamination of capacitor materials, particularly from flux and solvent residues. [2]

  5. Equivalent series resistance - Wikipedia

    en.wikipedia.org/wiki/Equivalent_series_resistance

    Capacitors and inductors as used in electric circuits are not ideal components with only capacitance or inductance.However, they can be treated, to a very good degree of approximation, as being ideal capacitors and inductors in series with a resistance; this resistance is defined as the equivalent series resistance (ESR) [1].

  6. ESR meter - Wikipedia

    en.wikipedia.org/wiki/ESR_meter

    Measuring ESR can be done by applying an alternating voltage at a frequency at which the capacitor's reactance is negligible, in a voltage divider configuration. It is easy to check ESR well enough for troubleshooting by using an improvised ESR meter comprising a simple square-wave generator and oscilloscope, or a sinewave generator of a few tens of kilohertz and an AC voltmeter, using a known ...

  7. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    Instantaneous current declines to steady-state current as the capacitor reaches full charge. In the case of open circuit, the capacitor will be charged to the peak AC voltage (one cannot actually charge a capacitor with AC line power, so this refers to a varying but unidirectional voltage; e.g., the voltage output from a rectifier).