  2. North American Fire Hose Coupler Incompatibilities - Wikipedia

    en.wikipedia.org/wiki/North_American_Fire_Hose...

    According to NFPA 1963, all U.S. fire hydrants should have the following ports: 2 + 1 ⁄ 2-inch attack port with 2.5-7.5 NH threads (two ports per hydrant; NFPA 1963 requirement) 4 + 1 ⁄ 2-inch pumper (steamer) port with either 4.5-4 NH threads or a 5-inch Storz port (one port per hydrant; NFPA 1963 requirement)

  3. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance. [3]

  4. Water flow test - Wikipedia

    en.wikipedia.org/wiki/Water_flow_test

    One hydrant is known as the residual hydrant or test hydrant and is located on or near the water main where a new water connection is desired. From this test hydrant, a static pressure and a residual pressure will be measured. The other hydrant, known as the flow hydrant, is usually the nearest hydrant away from the test hydrant.

  5. Storz - Wikipedia

    en.wikipedia.org/wiki/Storz

    The 100 mm (4-inch) and 125 mm (5-inch) Storz couplers have been specified in NFPA 1963, Standard for Fire Hose Connections, since the 1993 edition. U.S. cities that have fire hydrants with 125 mm Storz connectors include Raleigh, NC [ 5 ] and the City of Corvallis, OR (adapter on 4-inch threaded outlet).

  6. Standpipe (firefighting) - Wikipedia

    en.wikipedia.org/wiki/Standpipe_(firefighting)

    External access point for fire sprinkler and dry standpipe at a building in San Francisco, US Antique wet standpipe preserved at Edison and Ford Winter Estates. A standpipe or riser is a type of rigid water piping which is built into multi-story buildings in a vertical position, or into bridges in a horizontal position, to which fire hoses can be connected, allowing manual application of water ...

  7. Fire pump - Wikipedia

    en.wikipedia.org/wiki/Fire_pump

    The main standard that governs fire pump fixed-place installations in North America is the National Fire Protection Association's NFPA 20 Standard for the Installation of Stationary Fire Pumps for Fire Protection. [1] Fire pumps are powered most commonly by an electric motor or a diesel engine, or, occasionally a steam turbine.

  8. Water tender - Wikipedia

    en.wikipedia.org/wiki/Water_tender

    A water tender operated by the United States Air Force Fire Protection. A water tender, sometimes known as a water tanker, is a type of firefighting apparatus that specializes in the transport of water from a water source to a fire scene. [1] Water tenders are capable of drafting water from a stream, lake or hydrant.

  9. National Fire Protection Association - Wikipedia

    en.wikipedia.org/wiki/National_Fire_Protection...

    Sparky the Fire Dog. Sparky the Fire Dog is the official mascot of the National Fire Protection Association. Created in 1951 to promote fire safety education for children, [9] [10] he is a Dalmatian dressed in firefighting gear. A children's book about Sparky by Don Hoffman was published in 2011.