enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. 1951 USAF resolution test chart - Wikipedia

    en.wikipedia.org/wiki/1951_USAF_resolution_test...

    Glass chart. A 1951 USAF resolution test chart is a microscopic optical resolution test device originally defined by the U.S. Air Force MIL-STD-150A standard of 1951. The design provides numerous small target shapes exhibiting a stepped assortment of precise spatial frequency specimens.

  3. Microscopic scale - Wikipedia

    en.wikipedia.org/wiki/Microscopic_scale

    In physics, the microscopic scale is sometimes regarded as the scale between the macroscopic scale and the quantum scale. [2] [3] Microscopic units and measurements are used to classify and describe very small objects. One common microscopic length scale unit is the micrometre (also called a micron) (symbol: μm), which is one millionth of a metre.

  4. Diffraction-limited system - Wikipedia

    en.wikipedia.org/wiki/Diffraction-limited_system

    Memorial in Jena, Germany to Ernst Karl Abbe, who approximated the diffraction limit of a microscope as = ⁡, where d is the resolvable feature size, λ is the wavelength of light, n is the index of refraction of the medium being imaged in, and θ (depicted as α in the inscription) is the half-angle subtended by the optical objective lens (representing the numerical aperture).

  5. Shape factor (image analysis and microscopy) - Wikipedia

    en.wikipedia.org/wiki/Shape_factor_(image...

    The aspect ratio is agreeable with an eyeball-estimate on a globe. Such an estimate on a typical flat map, using the Mercator projection, would be less accurate due to the distorted scale at high latitudes. The circularity is deceptively low, due to the fjords that give Greenland a very jagged coastline (see the coastline paradox). A low value ...

  6. Light sheet fluorescence microscopy - Wikipedia

    en.wikipedia.org/wiki/Light_sheet_fluorescence...

    The resolution at that time was limited to 10 µm laterally and 26 µm longitudinally but at a sample size in the millimeter range. The orthogonal-plane fluorescence optical sectioning microscope used a simple cylindrical lens for illumination. Further development and improvement of the selective plane illumination microscope started in 2004. [5]

  7. Vernier scale - Wikipedia

    en.wikipedia.org/wiki/Vernier_scale

    Only when a full ten marks are counted, is there alignment, because the tenth mark is 10/10—a whole main scale unit—short, and therefore aligns with the ninth mark on the main scale. (In simple words, each VSD = 0.9 MSD, so each decrement of length 0.1 adds 10 times to make one MSD only in 9 divisions of vernier scale division).

  8. Fluorescence correlation spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Fluorescence_correlation...

    Typically, the fit would have three free parameters—G(0), (), and —from which the diffusion coefficient and fluorophore concentration can be obtained. With the normalization used in the previous section, G (0) gives the mean number of diffusers in the volume <N>, or equivalently—with knowledge of the observation volume size—the mean ...

  9. PSF Lab - Wikipedia

    en.wikipedia.org/wiki/PSF_Lab

    PSF Lab is a software program that allows the calculation of the illumination point spread function (PSF) of a confocal microscope under various imaging conditions. The calculation of the electric field vectors is based on a rigorous, vectorial model that takes polarization effects in the near-focus region and high numerical aperture microscope objectives into account.

  1. Related searches microscope scale bar calculation worksheet answers download free full version with serial key

    what is a microscopic scalemicroscopic scale wikipedia