Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...
For example, a 4" pipe, with 1" of thermal insulation makes a 6" penetrant (1" pipe covering on each side of the pipe), plus two pipe sizes = an 8" sleeve, creating a 1" annulus. In case of insulated piping, the size of the insulation must be taken into account for the intended firestop certification listing .
During the IPS period, pipes were cast in halves and welded together, and pipe sizes referred to the inside diameters. [1] The inside diameters under IPS were roughly the same as the more modern Ductile Iron Pipe Standard (DIPS) and Nominal Pipe Size (NPS) Standards, and some of the wall thicknesses were also retained with a different ...
Designating the outside diameter allows pipes of the same size to be fit together no matter what the wall thickness. For pipe sizes less than NPS 14 inch (DN 350), both methods give a nominal value for the OD that is rounded off and is not the same as the actual OD. For example, NPS 2 inch and DN 50 are the same pipe, but the actual OD is 2.375 ...
While pipe sizes in Australia are inch-based, they are classified by outside rather than inside diameter (e.g., a nominal 3 ⁄ 4 inch copper pipe in Australia has measured diameters of 0.750 inches outside and 0.638 inches inside, whereas a nominal 3 ⁄ 4 inch copper pipe in the U.S. and Canada has measured diameters of 0.875 inch outside and ...
Because of the pipe wall thickness of Schedule pipe, the actual diameter of the NPT threads is larger than the Nominal Pipe Size diameter, and considerably so for small sizes. Pipe of a given size in a different Schedule than Schedule 40 provides a different wall thickness while maintaining the same outside diameter and thread profile as ...
the thread size; Threads are normally right-hand. For left-hand threads, the letters, LH, are appended. Example: Pipe thread EN 10226 Rp 2 + 1 ⁄ 2. The terminology for the use of G and R originated from Germany (G for gas, as it was originally designed for use on gas pipes; R for rohr, meaning pipe.)
The application of thermal pipe insulation introduces thermal resistance and reduces the heat flow. Thicknesses of thermal pipe insulation used for saving energy vary, but as a general rule, pipes operating at more-extreme temperatures exhibit a greater heat flow and larger thicknesses are applied due to the greater potential savings. [3]