enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    For example, the United States National Electrical Code, Table 310.15(B)(16), specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30 °C, the conductor surface temperature allowed to be 75 °C. A single insulated conductor ...

  3. International Annealed Copper Standard - Wikipedia

    en.wikipedia.org/wiki/International_Annealed...

    Sometime around 1913, several copper samples from 14 important refiners and wire manufacturers were analyzed by the U.S. Bureau of Standards. The average resistance of the samples was determined to be 0.15292 Ω for copper wires with a mass of 1 gram of uniform cross section and 1 meter in length at 20 °C. In the United States this is usually ...

  4. Mineral-insulated copper-clad cable - Wikipedia

    en.wikipedia.org/wiki/Mineral-insulated_copper...

    If the MI cable jacket has been damaged, the magnesium oxide will wick moisture into the cable, and it will lose its insulating properties, causing shorts to the copper cladding and thence to earth. It is often necessary to remove 0.5 to 2 metres (1.6 to 6.6 ft) of the MI cable and splice in a new section to accomplish the repair.

  5. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  6. Overhead power line - Wikipedia

    en.wikipedia.org/wiki/Overhead_power_line

    Bundle conductors consist of several parallel cables connected at intervals by spacers, often in a cylindrical configuration. The optimum number of conductors depends on the current rating, but typically higher-voltage lines also have higher current. American Electric Power [16] is building 765 kV lines using six conductors per phase in a ...

  7. Power cable - Wikipedia

    en.wikipedia.org/wiki/Power_cable

    Power cables use stranded copper or aluminum conductors, although small power cables may use solid conductors in sizes of up to 1/0. (For a detailed discussion on copper cables, see: Copper wire and cable.). The cable may include uninsulated conductors used for the circuit neutral or for ground (earth) connection.

  8. High-voltage cable - Wikipedia

    en.wikipedia.org/wiki/High-voltage_cable

    High voltage is defined as any voltage over 1000 volts. [3] Those of 2 to 33 kV are usually called medium voltage cables, those over 50 kV high voltage cables.. Modern HV cables have a simple design consisting of a few parts: the conductor, the conductor shield, the insulation, the insulation shield, the metallic shield, and the jacket.

  9. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Also, the size of the aluminum wire needs to be larger compared to copper wire used for the same circuit due to the increased resistance of the aluminum alloys. For example, a 15 A branch circuit supplying standard lighting fixtures can be installed with either #14 AWG copper building wire or #12 AWG aluminum building wire according to the NEC ...