enow.com Web Search

  1. Ad

    related to: sump pump outlet keeps tripping reset button 2

Search results

  1. Results from the WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or ...

  3. Sump pump - Wikipedia

    en.wikipedia.org/wiki/Sump_pump

    Sump pumps are used where basement flooding may otherwise happen, and to solve dampness where the water table is near or above the foundation of a structure. Sump pumps send water away from a location to any place where it is no longer problematic, such as a municipal storm drain, a dry well, or simply an open-air site downhill from the building (sometimes called "pumping to daylight").

  4. Electrical outlet tester - Wikipedia

    en.wikipedia.org/wiki/Electrical_outlet_tester

    A receptacle tester being used to check for some types of improper wiring of an outlet. For this particular tester, proper wiring is indicated by the two yellow lights. The outlet tester checks that each contact in the outlet appears to be connected to the correct wire in the building's electrical wiring. It can identify several common wiring ...

  5. Earth-leakage protection device - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    Another cause of nuisance tripping is due to accumulated or burden currents caused by items with lowered insulation resistance. This may occur due to older equipment, or equipment with heating elements, or even wiring in buildings in the tropics where prolonged damp and rain conditions can cause the insulation resistance to lower due to ...

  6. Reset button technique - Wikipedia

    en.wikipedia.org/wiki/Reset_button_technique

    In many series, the reset button trope is used as a standard, and frequently explicit, plot device. Implicit usage of the technique can be seen in episodic fiction, such as when the results of episodes regularly cause what would seem to be massive changes in the status of characters and their world; however, it is understood by

  7. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    2. A listed branch/feeder-type AFCI that is installed at the origin of the branch circuit working in combination with the listed outlet branch-circuit-type AFCI (OBC AFCI) installed at the first outlet box which must also be marked that it is the first outlet box of the branch circuit. 3.

  8. Tripping (pipe) - Wikipedia

    en.wikipedia.org/wiki/Tripping_(pipe)

    Tripping pipe (or "Making a round trip" or simply "Making a trip") is the physical act of pulling the drill string out of the wellbore and then running it back in. This is done by physically breaking out or disconnecting (when pulling out of the hole) every other 2 or 3 joints of drill pipe at a time (called a stand ) and racking them ...

  9. Oil pump (internal combustion engine) - Wikipedia

    en.wikipedia.org/wiki/Oil_pump_(internal...

    The type of pump used varies. Gear pumps [1] [2] trochoid pumps [3] and vane pumps [a] are all commonly used. Plunger pumps have been used in the past, but these are now only used rarely, for small engines. To avoid the need for priming, the pump is always mounted low-down, either submerged or around the level of the oil in the sump. A short ...

  1. Ad

    related to: sump pump outlet keeps tripping reset button 2