enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Polarography - Wikipedia

    en.wikipedia.org/wiki/Polarography

    Heyrovský's Polarograph. Polarography is an electrochemical voltammetric technique that employs (dropping or static) mercury drop as a working electrode. In its most simple form polarography can be used to determine concentrations of electroactive species in liquids by measuring their mass-transport limiting currents.

  3. Oxygen sensor - Wikipedia

    en.wikipedia.org/wiki/Oxygen_sensor

    The optode sensors can, however, work in the whole region 0% to 100% oxygen saturation in water, and the calibration is done the same way as with the Clark-type sensor. No oxygen is consumed, and hence the sensor is insensitive to stirring, but the signal will stabilize more quickly if the sensor is stirred after being put in the sample.

  4. Electroanalytical methods - Wikipedia

    en.wikipedia.org/wiki/Electroanalytical_methods

    Chronoamperometry is the technique in which the current is measured, at a fixed potential, at different times since the start of polarisation. Chronoamperometry is typically carried out in unstirred solution and at the fixed electrode, i.e., under experimental conditions avoiding convection as the mass transfer to the electrode.

  5. Electro-galvanic oxygen sensor - Wikipedia

    en.wikipedia.org/wiki/Electro-galvanic_oxygen_sensor

    An electro-galvanic fuel cell is an electrochemical device which consumes a fuel to produce an electrical output by a chemical reaction. One form of electro-galvanic fuel cell based on the oxidation of lead is commonly used to measure the concentration of oxygen gas in underwater diving and medical breathing gases.

  6. Voltammetry - Wikipedia

    en.wikipedia.org/wiki/Voltammetry

    The reference is the most complex of the three electrodes; there are a variety of standards used. For non-aqueous work, IUPAC recommends the use of the ferrocene/ferrocenium couple as an internal standard. [8] In most voltammetry experiments, a bulk electrolyte (also known as a supporting electrolyte) is used to minimize solution resistance. It ...

  7. Electrochemical gas sensor - Wikipedia

    en.wikipedia.org/wiki/Electrochemical_gas_sensor

    Sensors are usually designed so that the gas supply is limited by diffusion, and thus the output from the sensor is linearly proportional to the gas concentration. This linear output is one of the advantages of electrochemical sensors over other sensor technologies (e.g. infrared), whose output must be linearized before they can be used.

  8. Differential pulse voltammetry - Wikipedia

    en.wikipedia.org/wiki/Differential_pulse_voltammetry

    The system of this measurement is usually the same as that of standard voltammetry.The potential between the working electrode and the reference electrode is changed as a pulse from an initial potential to an interlevel potential and remains at the interlevel potential for about 5 to 100 milliseconds; then it changes to the final potential, which is different from the initial potential.

  9. Clark electrode - Wikipedia

    en.wikipedia.org/wiki/Clark_electrode

    A schematic representation of Clark's 1962 invention, the Oxygen Electrode. The Clark electrode [1] [2] is an electrode that measures ambient oxygen partial pressure in a liquid using a catalytic platinum surface according to the net reaction: [3]

  1. Related searches galvanic vs polarographic do probes work based on the way they move in different

    polarographic potentialpolarographic half potential
    polarography limiting current