enow.com Web Search

  1. Ads

    related to: mcq on circuit breakers with test

Search results

  1. Results from the WOW.Com Content Network
  2. Transient recovery voltage - Wikipedia

    en.wikipedia.org/wiki/Transient_Recovery_Voltage

    Examples of TRV waveshapes. A transient recovery voltage (TRV) for high-voltage circuit breakers is the voltage that appears across the terminals after current interruption. It is a critical parameter for fault interruption by a high-voltage circuit breaker, its characteristics (amplitude, rate of rise) can lead either to a successful current interruption or to a failure (called reignition or ...

  3. Sulfur hexafluoride circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Sulfur_hexafluoride...

    Sulfur hexafluoride circuit breakers protect electrical power stations and distribution systems by interrupting electric currents, when tripped by a protective relay. Instead of oil, air, or a vacuum, a sulfur hexafluoride circuit breaker uses sulfur hexafluoride (SF 6) gas to cool and quench the arc on opening a circuit. Advantages over other ...

  4. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  5. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    A circuit breaker is an electrical safety device designed to protect an electrical circuit from damage caused by current in excess of that which the equipment can safely carry (overcurrent). Its basic function is to interrupt current flow to protect equipment and to prevent fire.

  6. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    During those 1.5 cycles, other separate circuits can see voltage dips or blinks until the affected circuit opens to stop the fault current. Automatically closing the breaker after it has tripped and stayed open for a brief amount of time, usually after 1 to 5 seconds, is a standard procedure. [5]

  7. Vacuum interrupter - Wikipedia

    en.wikipedia.org/wiki/Vacuum_interrupter

    Vacuum interrupter with ceramic housing. In electrical engineering, a vacuum interrupter is a switch which uses electrical contacts in a vacuum. It is the core component of medium-voltage circuit-breakers, generator circuit-breakers, and high-voltage circuit-breakers.

  8. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    The prospective short-circuit current that can occur under short circuit conditions should not exceed the rated breaking capacity of the apparatus, otherwise breaking of the current cannot be guaranteed. The current breaking capacity corresponds to a certain voltage, so an electrical apparatus may have more than one breaking capacity current ...

  9. Protective relay - Wikipedia

    en.wikipedia.org/wiki/Protective_relay

    In electrical engineering, a protective relay is a relay device designed to trip a circuit breaker when a fault is detected. [ 1 ] : 4 The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current, overvoltage , reverse power flow ...

  1. Ads

    related to: mcq on circuit breakers with test