enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. EN 16034 - Wikipedia

    en.wikipedia.org/wiki/EN_16034

    EN 16034 is a set of European standards which specify the technical performance characteristics for fire resistant and smoke control products, such as fire doors. Compliance with this standard requires to fulfill the requirements of the Construction Product Regulation [1] for construction products (short CPR).

  3. Firewall (construction) - Wikipedia

    en.wikipedia.org/wiki/Firewall_(construction)

    There are three main classifications of fire rated walls: fire walls, fire barriers, and fire partitions. A firewall is an assembly of materials used to delay the spread of fire a wall assembly with a prescribed fire resistance duration and independent structural stability. This allows a building to be subdivided into smaller sections.

  4. Fire door - Wikipedia

    en.wikipedia.org/wiki/Fire_door

    Fire-resistance rated door, with wire mesh glass vision panel Industrial grade fire door rated to hydrocarbon curve and blast resistance Double fire door immediately after 3-hour fire test inside a 4-hour rated Durasteel wall Double fire door after 3-hour fire test in a 4-hour Durasteel wall, during successful 45PSI (3.1 bar) hose stream test leading to a UL Listing [1]

  5. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    Fire-resistance rated wall assembly with fire door, cable tray penetration and intumescent cable coating. Passive fire protection (PFP) is components or systems of a building or structure that slows or impedes the spread of the effects of fire or smoke without system activation, and usually without movement. [1]

  6. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    The length of time required for a penetrant or sample on average to exceed a specified average heat rise above ambient at any single location determines the duration for the FT Rating (Fire and Temperature). If a hose-stream test is passed afterwards, the rating can then be expressed as an FTH Rating (Fire, Temperature and Hose-stream). The ...

  7. Fire damper - Wikipedia

    en.wikipedia.org/wiki/Fire_damper

    Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to ...

  8. Flue - Wikipedia

    en.wikipedia.org/wiki/Flue

    Fireplaces are one of the biggest energy wasters when the flue is not used properly. This occurs when the flue is left open too wide after the fire is started. Known as convection, warm air from the house is pulled up the chimney, while cold air from outside is pulled into the house wherever it can enter, including around leaking windows and ...

  9. Penetration (firestop) - Wikipedia

    en.wikipedia.org/wiki/Penetration_(firestop)

    A penetration, in firestopping, is an opening, such as one created by the use of a cast-in-place sleeve, in a wall or floor assembly required to have a fire-resistance rating, for the purpose of accommodating the passage of a mechanical, electrical, or structural penetrant. [1] The penetration may or may not contain a firestop system.