Search results
Results from the WOW.Com Content Network
Crystals used in X-ray crystallography may be smaller than a millimeter across. Although crystallography can be used to characterize the disorder in an impure or irregular crystal, crystallography generally requires a pure crystal of high regularity to solve the structure of a complicated arrangement of atoms.
These scattering methods generally use monochromatic X-rays, which are restricted to a single wavelength with minor deviations. A broad spectrum of X-rays (that is, a blend of X-rays with different wavelengths) can also be used to carry out X-ray diffraction, a technique known as the Laue method.
RHEED is used to interrogate surface structure. [1] [2] Surface X-ray diffraction (SXRD), which is similar to RHEED but uses X-rays, and is also used to interrogate surface structure. [3] X-ray standing waves, another X-ray variant where the intensity decay into a sample from diffraction is used to analyze chemistry. [4]
This is an X-ray diffraction pattern formed when X-rays are focused on a crystalline material, in this case a protein. Each dot, called a reflection, forms from the coherent interference of scattered X-rays passing through the crystal.
X-ray diffraction computed tomography, often abbreviated as XRD-CT, typically refers to the technique invented by Harding et al. [1] which assumes that the acquired data are powder diffraction data. For this reason, it has also been mentioned as powder diffraction computed tomography [ 7 ] and diffraction scattering computed tomography (DSCT ...
To determine the crystallographic orientation of the grains in the considered sample, the following software packages are in use: Fable [8] and GrainSpotter. [9] Reconstructing the 3D shape of the grains is nontrivial and three approaches are available to do so, respectively based on simple back-projection, forward projection, algebraic ...
X-ray absorption spectroscopy (XAS) is a widely used technique for determining the local geometric and/or electronic structure of matter. [1] The experiment is usually performed at synchrotron radiation facilities, which provide intense and tunable X-ray beams. Samples can be in the gas phase, solutions, or solids. [2]
Laboratory X-ray diffraction equipment relies on the use of an X-ray tube, which is used to produce the X-rays. The most commonly used laboratory X-ray tube uses a copper anode, but cobalt and molybdenum are also popular. The wavelength in nm varies for each source. The table below shows these wavelengths, determined by Bearden [14] (all values ...