For example, an auto transformer that adapts a 1000 VA load rated at 120 volts to a 240 volt supply has an equivalent rating of at least: 1,000 VA (240 V – 120 V) / 240 V = 500 VA. However, the actual rating (shown on the tally plate) must be at least 1000 VA.
Distribution transformers typically have ratings less than 200 kVA, [3] although some national standards allow units up to 5000 kVA to be described as distribution transformers. Since distribution transformers are energized 24 hours a day (even when they don't carry any load), reducing iron losses is vital in their design. They usually don't ...
Current transformers used for protective relaying also have accuracy requirements at overload currents in excess of the normal rating to ensure accurate performance of relays during system faults. A CT with a rating of 2.5L400 specifies with an output from its secondary winding of twenty times its rated secondary current (usually 5 A × 20 ...
Consequently, the transformers used to step-down the high overhead line voltages were much larger and heavier for the same power rating than those required for the higher frequencies. Power transformer overexcitation condition caused by decreased frequency; flux (green), iron core's magnetic characteristics (red) and magnetizing current (blue).
A capacitor voltage transformer (CVT), is a transformer used in power systems to step down extra high voltage signals and provide a low voltage signal to the actual VT (voltage transformer) used for operating metering/protective relays due to a lower cost than an electromagnetic PT. The circuit diagram for a simple capacitor voltage transformer
Other advantages of autotransformers include lower leakage reactance, lower losses, lower excitation current, and increased VA rating for a given size and mass. [ 2 ] An example of an application of an autotransformer is one style of traveler's voltage converter , that allows 230-volt devices to be used on 120-volt supply circuits, or the reverse.
The ratio of the voltage bases on either side of a transformer is selected to be the same as the ratio of the transformer voltage ratings. With these two rules, a per-unit impedance remains unchanged when referred from one side of a transformer to the other. This allows the ideal transformer to be eliminated from a transformer model.
Pad-mounted transformers are made in power ratings from around 15 to around 5000 kVA and often include built-in fuses and switches. Primary power cables may be connected with elbow connectors, which can be operated when energized using a hot stick and allows for flexibility in repair and maintenance.