High voltage interface relays, a.k.a., interface relays: [1] [2] or coupling relays or insulating interfaces [3] [4] is a special class of electrical relays designed to provide informational and electrical compatibility between functional components isolated from each other and not allowing for a direct connection due to a high difference of potentials.
The time period can be varied by increasing or decreasing the flow rate. For longer time periods, a mechanical clockwork timer is installed. Relays may be arranged for a fixed timing period, or may be field-adjustable, or remotely set from a control panel. Modern microprocessor-based timing relays provide precision timing over a great range.
A solid state relay (SSR) is an electronic switching device that switches on or off when an external voltage (AC or DC) is applied across its control terminals. They serve the same function as an electromechanical relay , but solid-state electronics contain no moving parts and have a longer operational lifetime.
In addition, other items external to the relay rack such as pumps, heaters, and so forth would also be shown on the ladder diagram. Ladder logic has evolved into a programming language that represents a program by a graphical diagram based on the circuit diagrams of relay logic hardware.
The relays can also be classified on the type of power source that they use to work. A dual powered protection relay powered by the current obtained from the line by a CT. The striker is also shown. Self-powered relays operate on energy derived from the protected circuit, through the current transformers used to measure line current, for example.
Current and voltage transformers to step down the high voltages and currents of the electrical power system to convenient levels for the relays to deal with; Protective relays to sense the fault and initiate a trip, or disconnection, order; Circuit breakers or RCDs to open/close the system based on relay and autorecloser commands
The redundant design ensures that wiring errors do not lead to the loss of the safety function. Two relays (K1, K2) with positive-guided contacts provide the safe switching contacts. The two input circuits CH1 and CH2 each activate one of the two internal relays. The circuit is activated via the start relay K3.
The National Association of Relay Manufacturers and its successor, the Relay and Switch Industry Association define 23 distinct forms of electrical contact found in relays and switches. [ 12 ] A normally closed ( NC ) contact pair is closed (in a conductive state) when it, or the device operating it, is in a deenergized state or relaxed state.