In a step-up transformer, conversely, the load is attached across the full winding while the source is connected to a tap across a portion of the winding. For a step-up transformer, the subscripts in the above equations are reversed where, in this situation, N 2 {\displaystyle N_{2}} and V 2 {\displaystyle V_{2}} are greater than N 1 ...
A transformer or autotransformer can be used; (auto)transformers are inherently reversible, so the same transformer can be used to step the voltage up, or step it down by the same ratio. Lighter and smaller devices can be made using electronic circuitry; reducing the voltage electronically is simpler and cheaper than increasing it.
Increasing the voltage produced by electric power generation for efficient transmission over long distances, using step-up transformers [8] [9] Interconnection of different power grids [8] Reducing the voltage from transmission to lower-voltage distribution lines that supply individual homes or businesses [8] [9]
In electrical engineering, isolated-phase bus (IPB), also known as phase-isolated bus (PIB) in some countries, is a method of construction for circuits carrying very large currents, typically between a generator and its step-up transformer in a steam or large hydroelectric power plant. Isolated phase bus during installation at the Bui Dam Ghana ...
A schematic representation of long distance electric power transmission. From left to right: G=generator, U=step-up transformer, V=voltage at beginning of transmission line, Pt=power entering transmission line, I=current in wires, R=total resistance in wires, Pw=power lost in transmission line, Pe=power reaching the end of the transmission line, D=step-down transformer, C=consumers.
The core material a coil is wrapped around can increase its inductance dramatically – hundreds to thousands of times more than “air” – thereby raising the transformer's Q. The cores of such transformers tend to help performance the most at the lower end of the frequency band transformer was designed for.
Historical precedent makes transformer manufacturers hesitant to scale up production too quickly. The same companies went into overdrive to meet rising electrical demand during the pre-2008 ...
A further transient problem is that with a single coil construction and a star switch, the autotransformer acts as a step-up transformer during the <5 microsecond period at contact separation of the Star point switch. With the motor connected to the 80% voltage tap there will be an escalation of the transient by 5:1 ratio.