  2. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    The base value should only be a magnitude, while the per-unit value is a phasor. The phase angles of complex power, voltage, current, impedance, etc., are not affected by the conversion to per unit values. The purpose of using a per-unit system is to simplify conversion between different transformers.

  3. Nominal power (photovoltaic) - Wikipedia

    en.wikipedia.org/wiki/Nominal_power_(photovoltaic)

    In the context of domestic PV installations, the kilowatt (symbol kW) is the most common unit for nominal power, for example P peak = 1 kW. Colloquial English sometimes conflates the quantity power and its unit by using the non-standard label watt-peak (symbol W p), possibly prefixed as in kilowatt-peak (kW p), megawatt-peak (MW p), etc.

  4. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    To get 1 kW of real power at 0.2 power factor, 5 kVA of apparent power needs to be transferred (1 kW ÷ 0.2 = 5 kVA). This apparent power must be produced and transmitted to the load and is subject to losses in the production and transmission processes.

  5. Electric power - Wikipedia

    en.wikipedia.org/wiki/Electric_power

    Electric power is the rate of transfer of electrical energy within a circuit.Its SI unit is the watt, the general unit of power, defined as one joule per second.Standard prefixes apply to watts as with other SI units: thousands, millions and billions of watts are called kilowatts, megawatts and gigawatts respectively.

  6. Single-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Single-phase_electric_power

    In North America, individual residences and small commercial buildings with services up to about 100 kVA (417 amperes at 240 volts) will usually have three-wire single-phase distribution, especially in rural areas where motor loads are small and uncommon.

  7. Kilowatt-hour - Wikipedia

    en.wikipedia.org/wiki/Kilowatt-hour

    The notation kW/h for the kilowatt-hour is incorrect, as it denotes kilowatt per hour. The hour is a unit of time listed among the non-SI units accepted by the International Bureau of Weights and Measures for use with the SI. [6] An electric heater consuming 1,000 watts (1 kilowatt) operating for one hour uses one kilowatt-hour of energy.

  8. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The neutral current can be determined by adding the three phase currents together as complex numbers and then converting from rectangular to polar co-ordinates. If the three-phase root mean square (RMS) currents are I L 1 {\displaystyle I_{L1}} , I L 2 {\displaystyle I_{L2}} , and I L 3 {\displaystyle I_{L3}} , the neutral RMS current is:

  9. Nameplate capacity - Wikipedia

    en.wikipedia.org/wiki/Nameplate_capacity

    Nameplate capacity, also known as the rated capacity, nominal capacity, installed capacity, maximum effect or gross capacity, [1] is the intended full-load sustained output of a facility such as a power station, [2] [3] electric generator, a chemical plant, [4] fuel plant, mine, [5] metal refinery, [6] and many others.