The term subcooling (also called undercooling) refers to the intentional process of cooling a liquid below its normal boiling point. For example, water boils at 373 K; at room temperature (293 K) liquid water is termed "subcooled". Subcooling is a common stage in refrigeration cycles and steam turbine cycles.
Superheating can occur when an undisturbed container of water is heated in a microwave oven.At the time the container is removed, the lack of nucleation sites prevents boiling, leaving the surface calm.
It is possible, at a given pressure, to superheat a liquid above its boiling point without it becoming gaseous. Supercooling should not be confused with freezing-point depression. Supercooling is the cooling of a liquid below its freezing point without it becoming solid.
The incorporation of a subcooling stage after the receiver reduces even more the chances to observe flash gas. [5] This subcooling may be done in a reserved portion of the main condenser, or separately with a heat exchanger. Some receivers may incorporate an internal heat exchanger that draws heat form the subcooled liquid to superheat the gas ...
Superheat may refer to: Superheating, in physics; Superheater, for steam engine superheat; Superheat, live 2000 album by Dutch band The Gathering
A thermal expansion valve is a key element to a heat pump; this is the cycle that makes air conditioning, or air cooling, possible.A basic refrigeration cycle consists of four major elements: a compressor, a condenser, a metering device and an evaporator.
The subcooling term refers to cooling the liquid below its boiling point. 10 °F (5.6 °C) of subcooling means it is 10 °F colder than boiling at a given pressure. As it represents a difference of temperatures, the subcooling value is not measured on an absolute temperature scale, only on a relative scale as a temperature difference.
As the formula shows, the COP of a heat pump system can be improved by reducing the temperature gap (=) at which the system works. For a heating system this would mean two things: For a heating system this would mean two things: