Inexpensive analog meters may have only a single resistance scale, seriously restricting the range of precise measurements. Typically, an analog meter will have a panel adjustment to set the zero-ohms calibration of the meter, to compensate for the varying voltage of the meter battery, and the resistance of the meter's test leads.
First, the meter needs to be zeroed by shorting the measurement points together and performing an adjustment for zero ohms indication prior to each measurement. This is because as the battery voltage decreases with age, the series resistance in the meter needs to be reduced to maintain the zero indication at full deflection.
Megohmmeter M1101M. A Megohmmeter or insulation resistance tester, is a special type of ohmmeter used to measure the electrical resistance of insulators. [1] Insulating components, for example cable jackets, must be tested for their insulation strength at the time of commissioning and as part of maintenance of high voltage electrical equipment and installations.
Possibly the best known multimeter of the range was the Model 8, which was produced in various versions from May 1951 until 2008; the last version was the Mark 7. The multimeter is often called simply an AVO, because the company logo carries the first letters of 'amps', 'volts' and 'ohms'. The design concept is due to the Post Office engineer ...
Isolation resistance measurements may be achieved using a high input impedance ohmmeter, digital multimeter (DMM) or current-limited Hipot test instrument. The selected equipment should not over-stress sensitive electronic components comprising the subsystem.
Measuring ESR can be done by applying an alternating voltage at a frequency at which the capacitor's reactance is negligible, in a voltage divider configuration. It is easy to check ESR well enough for troubleshooting by using an improvised ESR meter comprising a simple square-wave generator and oscilloscope, or a sinewave generator of a few tens of kilohertz and an AC voltmeter, using a known ...
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
A tube with low emission will work perfectly fine in most circuits, and need not be replaced on that indication alone, unless it measures much lower than specified or if it indicates a short. A variation on the emission tester is the dynamic conductance tester , a type of tester developed by the Jackson Electrical Company of Dayton, Ohio.