Rate-of-Rise (ROR) heat detectors operate on a rapid rise in element temperature of 6.7 to 8.3°C (12.1 to 14.9°F) increase per minute, irrespective of the starting temperature. This type of heat detector can operate at a lower temperature fire condition than would be possible if the threshold were fixed.
Linear heat detection (LHD) (also known as linear detection wire or linear heat detection cable or linear heat) is a very commonly used method of fire detection. It can detect a fire anywhere along the length of the cable, and can be of lengths in excess of a kilometer. Applications can range from building fire alarm systems to mobile plant ...
A fire alarm control panel Fire alarm speaker and pull station. Fire alarm systems are composed of several distinct parts: Fire alarm control panel (FACP), or fire alarm control unit (FACU): This component, the hub of the system, monitors inputs and system integrity, controls outputs, and transmits information.
The EN 54 series of standards covers the following topics and product groups related to fire detection and fire alarm systems: [6] [7] Introduction: the introduction to the series of standards contains a diagram of a fire alarm system as well as numerous definitions of terms that are used in the other parts of the series of standards.
The majority of guidance available for design of heat and smoke building vents installed in buildings is restricted to nonsprinklered, single-story buildings. [4] This is partly a historical consequence of the installation of heat and smoke vents following the August 1953 General Motors, Livonia, MI major fire in a nonsprinklered manufacturing facility which effectively stopped the production ...
Coded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel, which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset ...
In 2000, the Los Angeles Times called the thermal imaging camera "[p]erhaps the best advance in fire equipment in the last 25 years—and the most expensive". [23] Fire departments have pursued various sources and methods to fund thermal imaging cameras including direct budgeting, [6] grants, [9] and charity donations, [24] among others.
Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to ...