ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...
[4] The model code, IECC, and the standard, ASHRAE 90.1, apply to commercial buildings. [5] [4] [6] The IECC references several ASHRAE Standards, in particular, ASHRAE 90.1 for commercial building construction. [22] Being a part of the ICC’s collection of model codes, the IECC is revised annually and published in full-form every three years.
ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]
The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) provides lighting standards in ASHRAE 90.1-2004. EPAct of 2005 set a deadline for states to adopt the ASHRAE 90.1-2004 standards. [19] ASHRAE has recently published the 90.1-2010 with improved lighting standards, this includes:
The IGCC will reference the Public Version 1.0/ ANSI/ASHRAE/USGBC/IES Standard 189.1-2009 for the Design of High-Performance Green Buildings, Except Low-Rise Residential Buildings, as an alternative jurisdictional compliance option within the IGCC. The participants in designing this Standard also voiced their support for the new IGCC and its ...
Space By Space Method. A defined list of many possible space types within a building the associated watts per square foot allowance. For example, ANSI/ASHRAE/IESNA Standard 90.1-2007 allows the Emergency Space of a hospital to be designed for 2.7 watts per square foot, but the Recovery areas of a hospital would be allowed 0.8 watts per square foot.
There are two major systems to classify ductwork airtightness, one based on European standards, the other based on ASHRAE standard 90.1-2010.Both are based on the leakage airflow rate at a given ductwork pressure divided by the product of the ductwork surface area and the same ductwork pressure raised to the power 0.65.