enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    Duct leakage test in the US. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.

  3. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    Duct leakage testing of forced air heating/cooling systems - both supply (vents) ducts and return ducts can be tested to determine if and how much they leak air. A duct test can be combined with a blower door test to measure the total leakage to outside, measuring effective leakage to the outside of the house only.

  4. Section 608 - Wikipedia

    en.wikipedia.org/wiki/Section_608

    An initial verification test must then be done within 30/120 days, and then a follow-up test within 10 days of that. There are additional clauses for extensions if needed. If the leak is not to be repaired, there must be a plan to retire or retrofit the appliance within 30 days, to be completed within one year. [10]

  5. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law model between the airflow rate and the pressure difference across the ductwork envelope as follows: q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in L.s −1; C L is the air leakage coefficient expressed in L.s −1.Pa −n

  6. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.

  7. Air Movement and Control Association - Wikipedia

    en.wikipedia.org/wiki/Air_Movement_and_Control...

    ANSI/AMCA Standard 510 - Methods of Testing Heavy Duty Dampers for Rating establishes testing methods to be used in measuring the performance of dampers generally described as “custom design,” “heavy duty” or “severe service” normally used in applications where elevated temperature, erosion and/or corrosion conditions exist ...

  8. Forced-air gas - Wikipedia

    en.wikipedia.org/wiki/Forced-air_gas

    Each room has an outlet from the duct system, often mounted in the floor or low on the wall – some rooms will also have an opening into the cold air return duct. Depending on the age of the system, forced-air gas furnaces use either a pilot light or a solid-state ignition system (spark or hot surface ignition) to light the natural gas burner ...

  9. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    UFAD leakage that does not contribute to cooling, leading to wasted increased fan energy. UFAD leakage into the space, contributing to cooling. Leakage in UFAD supply plenums can be a major cause for inefficiency in a UFAD system. There are two types of leakageleakage into the space and leakage into pathways that bypass the space.