enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Heat pump and refrigeration cycle - Wikipedia

    en.wikipedia.org/wiki/Heat_pump_and...

    Vapor-compression refrigeration [6] For comparison, a simple stylized diagram of a heat pump's vapor-compression refrigeration cycle: 1) condenser, 2) expansion valve, 3) evaporator, 4) compressor (Note that this diagram is flipped vertically and horizontally compared to the previous one) [7] Temperature–entropy diagram of the vapor-compression cycle.

  3. Vapor-compression refrigeration - Wikipedia

    en.wikipedia.org/.../Vapor-compression_refrigeration

    A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.

  4. List of refrigerants - Wikipedia

    en.wikipedia.org/wiki/List_of_refrigerants

    This is a list of refrigerants, sorted by their ASHRAE-designated numbers, commonly known as R numbers. Many modern refrigerants are human-made halogenated gases, ...

  5. Cascade refrigeration - Wikipedia

    en.wikipedia.org/wiki/Cascade_refrigeration

    A two-cycle cascade refrigeration process schematic diagram. A cascade refrigeration cycle is a multi-stage thermodynamic cycle. An example two-stage process is shown at right. (Bottom on mobile) The cascade cycle is often employed for devices such as ULT freezers. [1] In a cascade refrigeration system, two or more vapor-compression cycles with ...

  6. Subcooling - Wikipedia

    en.wikipedia.org/wiki/Subcooling

    A small diagram of a refrigeration system with mechanical subcooling and superheating coupled by an internal heat exchanger (IHX) Subcooling is normally used so that when the refrigerant reaches the thermostatic expansion valve, all of it is in its liquid form, thus allowing the valve to work properly.

  7. Chlorodifluoromethane - Wikipedia

    en.wikipedia.org/wiki/Chlorodifluoromethane

    R-458A is for use in air conditioning and refrigeration applications, without capacity or efficiency loss. Works with MO, AB, and POE oils. [13] R-32 or HFC-32 (difluoromethane) is for use in air conditioning and refrigeration applications. It has zero ozone depletion potential (ODP) [2] and a global warming potential (GWP) index 675 times that ...

  8. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [1] [2] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs. The COP is used in thermodynamics.

  9. Air source heat pump - Wikipedia

    en.wikipedia.org/wiki/Air_source_heat_pump

    The cool liquid refrigerant then re-enters the outdoor heat exchanger coils to begin a new cycle. Each cycle usually takes a few minutes. [12] Most heat pumps can also operate in a cooling mode where the cold refrigerant is moved through the indoor coils to cool the room air. As of 2024 tech other than vapour compression is insignificant in the ...