Installed faced fiberglass batt insulation with its R-value visible (R-21) [1]. The R-value (in K⋅m 2 /W) is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]
This is a list of insulation materials used around the world. Typical R-values are given for various materials and structures as approximations based on the average of available figures and are sorted by lowest value. R-value at 1 m gives R-values normalised to a 1 metre (3 ft 3 in) thickness and sorts by median value of the range.
Closed-cell foams are superior insulators. While open-cell foams typically have R-values of 3 to 4 per inch (RSI-0.53 to RSI-0.70 per inch), closed-cell foams can attain R-values of 5 to 8 per inch (RSI-0.88 to RSI-1.41 per inch). This is important if space is limited, because it allows a thinner layer of insulation to be used.
For example, in the US the insulation standard for attics, is recommended to be at least R-38 US units, (equivalent to R-6.7 or a U value of 0.15 in SI units). [5] The equivalent standard in the UK are technically comparable, the approved document L would normally require an average U value over the roof area of 0.11 to 0.18 depending on the ...
Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)
Building insulation: Understanding thermal resistance helps in designing energy-efficient buildings with effective insulation materials to reduce heat transfer. Electronics cooling: Thermal resistance is crucial for designing heat sinks and thermal management systems in electronic devices to prevent overheating. Calculating thermal conductance ...
Very high levels of insulation, typically R-40 (RSI-7) walls and R-60 (RSI-10.6) roof, corresponding to SI U-values of 0.15 and 0.1 W/(m 2 ·K) respectively) Details to ensure insulation continuity where walls meet roofs, foundations, and other walls
This means that VIPs have about one-fifth the thermal conductivity of conventional insulation, and therefore about five times the thermal resistance per unit thickness. Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value ...