Schematic representation of a normal sinus rhythm EKG wave. In electrocardiography, the PR interval is the period, measured in milliseconds, that extends from the beginning of the P wave (the onset of atrial depolarization) until the beginning of the QRS complex (the onset of ventricular depolarization); it is normally between 120 and 200 ms in duration.
There are 6 different sinus arrhythmia. [1] [2]A normal heart should have a normal sinus rhythm, this rhythm can be identified by a ventricular rate of 60-100 bpm, at a regular rate, with a normal PR interval (0.12 to 0.20 second) and a normal QRS complex (0.12 second and less).
Electrocardiography is the process of producing an electrocardiogram (ECG or EKG [a]), a recording of the heart's electrical activity through repeated cardiac cycles. [4] It is an electrogram of the heart which is a graph of voltage versus time of the electrical activity of the heart [ 5 ] using electrodes placed on the skin.
If at least three different shaped P waves can be seen in a given ECG lead tracing, this implies that even if one of them arises from the SA node, at least two others are arising elsewhere. This is taken as evidence of multiple (i.e. at least two) ectopic foci , and is called multifocal (or more correctly, multiform) atrial rhythm if the rate ...
The term normal sinus rhythm (NSR) is sometimes used to denote a specific type of sinus rhythm where all other measurements on the ECG also fall within designated normal limits, giving rise to the characteristic appearance of the ECG when the electrical conduction system of the heart is functioning normally; however, other sinus rhythms can be ...
The fetal ST interval may be analyzed during labor (ST analysis) to identify fetuses at risk for asphyxia. Changes in the ST segment and increased T wave height (in relation to the QRS complex) are indications of fetuses at risk. (Neilson JP (2006). “Fetal electrocardiogram (ECG) for fetal monitoring during labour”. Cochrane Database.
The normal PR interval is from 120 ms to 200 ms in length. This is measured from the initial deflection of the P wave to the beginning of the QRS complex. [3] In first-degree heart block, the AV node conducts the electrical activity more slowly. This is seen as a PR interval greater than 200 ms in length on the surface ECG.
P=P wave, PR=PR interval, QRS=QRS complex, QT=QT interval, ST=ST segment, T=T wave Wiggers with jugular venous waveform Wiggers diagram with mechanical (echo), electrical (ECG), and aortic pressure (catheter) waveforms, together with an in-ear dynamic pressure waveform measured using a novel infrasonic hemodynography technology, for a patient ...