Search results
Results from the WOW.Com Content Network
The use of fetal scalp blood testing originated in Germany in 1961 and required 0.25 mL of blood drawn from the fetus. [1] As one of the first methods of monitoring fetal wellbeing during labor, there were many disadvantages including the need for at least 3 cm dilation of the mother and extreme precision from the physician performing the procedure. [9]
Intrauterine hypoxia can be attributed to maternal, placental, or fetal conditions. [12] Kingdom and Kaufmann classifies three categories for the origin of fetal hypoxia: 1) pre-placental (both mother and fetus are hypoxic), 2) utero-placental (mother is normal but placenta and fetus is hypoxic), 3) post-placental (only fetus is hypoxic).
Percutaneous umbilical cord blood sampling (PUBS), also called cordocentesis, fetal blood sampling, or umbilical vein sampling is a diagnostic genetic test that examines blood from the fetal umbilical cord to detect fetal abnormalities. [1] Fetal and maternal blood supply are typically connected in utero with one
Histopathology of placenta with increased syncytial knotting of chorionic villi, with two knots pointed out. The following characteristics of placentas have been said to be associated with placental insufficiency, however all of them occur in normal healthy placentas and full term healthy births, so none of them can be used to accurately diagnose placental insufficiency: [citation needed]
Fetal scalp stimulation test is a diagnostic test used to detect fetal metabolic acidemia. It can be used as a non-invasive alternative to fetal scalp blood testing . [ 1 ] [ 2 ]
Fetal distress, also known as non-reassuring fetal status, is a condition during pregnancy or labor in which the fetus shows signs of inadequate oxygenation. [1] Due to its imprecision, the term "fetal distress" has fallen out of use in American obstetrics. [2] [1] [3] The term "non-reassuring fetal status" has largely replaced it. [4]
Cord blood gas analysis can be used to determine if there is perinatal hypoxia/asphyxia, which are potential causes of hypoxic-ischemic encephalopathy or cerebral palsy, and give insight into causes of intrapartum fetal distress. [7] Cord blood gas analysis is indicated for high-risk pregnancies, in cases where C-sections occurred due to fetal ...
Persistent fetal circulation is a condition caused by a failure in the systemic circulation and pulmonary circulation to convert from the antenatal circulation pattern to the "normal" pattern. Infants experience a high mean arterial pulmonary artery pressure and a high afterload at the right ventricle.