enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Titration - Wikipedia

    en.wikipedia.org/wiki/Titration

    A reagent, termed the titrant or titrator, [2] is prepared as a standard solution of known concentration and volume. The titrant reacts with a solution of analyte (which may also be termed the titrand [3]) to determine the analyte's concentration. The volume of titrant that reacted with the analyte is termed the titration volume.

  3. Thermometric titration - Wikipedia

    en.wikipedia.org/wiki/Thermometric_titration

    Heat losses or gains from outside the system via the vessel walls and cover; Differences in the temperature between the titrant and the titrand; Evaporative losses from the surface of the rapidly mixed fluid; Heats of solution when the titrant solvent is mixed with the analyte solvent;

  4. Standard solution - Wikipedia

    en.wikipedia.org/wiki/Standard_solution

    The ratio of peak areas between the internal standard and analyte is calculated to determine analyte concentration. [12] A common type of internal standard is an isotopically labeled analogue of the analyte, which incorporates one or more atoms of 2 H, 13 C, 15 N and 18 O into its structure. [13]

  5. Analytical chemistry - Wikipedia

    en.wikipedia.org/wiki/Analytical_chemistry

    Although there are few examples of such systems competitive with traditional analysis techniques, potential advantages include size/portability, speed, and cost. (micro total analysis system (μTAS) or lab-on-a-chip). Microscale chemistry reduces the amounts of chemicals used. Many developments improve the analysis of biological systems.

  6. Karl Fischer titration - Wikipedia

    en.wikipedia.org/wiki/Karl_Fischer_titration

    Although KF is a destructive analysis, the sample quantity is small and is typically limited by the accuracy of weighing. For example, in order to obtain an accuracy of 1% using a scale with the typical accuracy of 0.2 mg, the sample must contain 20 mg water, which is e.g. 200 mg for a sample with 10% water.

  7. Total base number - Wikipedia

    en.wikipedia.org/wiki/Total_Base_Number

    In a titration, the titrant reacts with the analyte in the sample either exothermically or endothermically. The thermoprobe measures the temperature of the titrating solution. When all of the analyte in the sample has reacted with the titrant, the temperature of the solution will change, and the endpoint of the titration is revealed by an ...

  8. Gran plot - Wikipedia

    en.wikipedia.org/wiki/Gran_plot

    The Gran plot is based on the Nernst equation which can be written as = + ⁡ {+} where E is a measured electrode potential, E 0 is a standard electrode potential, s is the slope, ideally equal to RT/nF, and {H +} is the activity of the hydrogen ion.

  9. Coulometry - Wikipedia

    en.wikipedia.org/wiki/Coulometry

    The electrochemical generation of a titrant is much more sensitive and can be much more accurately controlled than the mechanical addition of titrant using a burette drive. For example, a constant current flow of 10 μA for 100 ms is easily generated and corresponds to about 10 micrograms of titrant.