A USAF 1951 resolution chart in PDF format is provided by Yoshihiko Takinami. This chart should be printed such that the side of the square of the 1st element of the group -2 should be 10 mm long. USAF 1951 Resolution Target Further explanations and examples; Koren 2003: Norman Koren's updated resolution chart better suited for computer analysis
For example, a 2-megapixel camera of 20-micrometre-square pixels will have worse resolution than a 1-megapixel camera with 8-micrometre pixels, all else being equal. For resolution measurement, film manufacturers typically publish a plot of Response (%) vs. Spatial Frequency (cycles per millimeter). The plot is derived experimentally.
Dawes' limit is a formula to express the maximum resolving power of a microscope or telescope. [1] It is so named after its discoverer, William Rutter Dawes, [2] although it is also credited to Lord Rayleigh. The formula takes different forms depending on the units.
A digital microscope is a variation of a traditional optical microscope that uses optics and a digital camera to output an image to a monitor, sometimes by means of software running on a computer. A digital microscope often has its own in-built LED light source, and differs from an optical microscope in that there is no provision to observe the ...
E.g. a microscope typically magnifies everything 10 to 100-fold, and a reflex camera will generally demagnify objects at a distance of 5 meter by a factor of 100 to 200. The resolution of a digital imaging device is not only limited by the optics, but also by the number of pixels, more in particular by their separation distance.
For scattered light imaging, instruments such as near-field scanning optical microscopes and nano-FTIR, which are built atop atomic force microscope systems, can be used to achieve up to 10-50 nm resolution. The data recorded by such instruments often requires substantial processing, essentially solving an optical inverse problem for each image.
A single, tiny source of light can be located much better than the resolution of a microscope usually allows for: although the light will produce a blurry spot, computer algorithms can be used to accurately calculate the center of the blurry spot, taking into account the point spread function of the microscope, the noise properties of the ...
In a dry objective or condenser, this gives a maximum NA of 0.95. In a high-resolution oil immersion lens, the maximum NA is typically 1.45, when using immersion oil with a refractive index of 1.52. Due to these limitations, the resolution limit of a light microscope using visible light is about 200 nm.