  2. Electrical bonding - Wikipedia

    en.wikipedia.org/wiki/Electrical_bonding

    Electrical bonding is the practice of intentionally electrically connecting all exposed metal items not designed to carry electricity in a room or building as protection from electric shock. Bonding is also used to minimize electrical arcing between metal surfaces with electrical potential differences.

  3. TIA-607-B - Wikipedia

    en.wikipedia.org/wiki/TIA-607-B

    Among TIA-607-B's list of metallic components in need of bonding are racks, enclosures, ladders, surge protectors, cable trays, routers, switches and patch panels. Following the bonding of telecom infrastructure components, the entire system must be bonded to the building's main ground, which is sometimes also referred to as a grounding ...

  4. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    Strictly speaking, the terms grounding or earthing are meant to refer to an electrical connection to ground/earth. Bonding is the practice of intentionally electrically connecting metallic items not designed to carry electricity. This brings all the bonded items to the same electrical potential as a protection from electrical shock.

  5. Isolated ground - Wikipedia

    en.wikipedia.org/wiki/Isolated_ground

    An isolated ground (IG) (or Functional Earth (FE) in European literature) is a ground connection to a local earth electrode from equipment where the main supply uses a different earthing arrangement, one of the common earthing arrangements used with domestic mains supplies.

  6. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    The diagram shows leakage current from an appliance such as an electric motor A flowing through the building's ground system G to the neutral wire at the utility ground bonding point at the service panel. The ground loop between components C1 and C2 creates a second parallel path for the current. [8]

  7. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Hot is any line or neutral conductor (wire or otherwise) connected with an electrical system that has electric potential relative to electrical ground or line to neutral. Ground is a safety conductor with a low impedance path to earth. It is often called the "ground wire," or safety ground. It is either bare or has green insulation. [1]

  8. Bonding jumper - Wikipedia

    en.wikipedia.org/wiki/Bonding_jumper

    [2] Some codes require a bonding jumper to be pulled into non-metallic conduit or in electrical metallic tubing that may be exposed to corrosion or mechanical damage. In North American electrical codes, an important bonding jumper is found in main electrical panels, where the system neutral conductor is connected to earth ground. This must be ...

  9. Groundbed - Wikipedia

    en.wikipedia.org/wiki/Groundbed

    For building electrical grounding systems or earthing systems, there is a low resistance conductor bonding the metalwork and this is connected to a groundbed. The electrodes for electrical grounding are often called ground rods and are often made from steel with a copper clad surface – typically 1 to 2 m long and 20 millimetres (0.79 in) in ...