ICP Plasma "torch". The ICP-AES is composed of two parts: the ICP and the optical spectrometer. The ICP torch consists of 3 concentric quartz glass tubes. [2] The output or "work" coil of the radio frequency (RF) generator surrounds part of this quartz torch. Argon gas is typically used to create the plasma.
Most analytical instruments produce a signal even when a blank (matrix without analyte) is analyzed.This signal is referred to as the noise level. The instrument detection limit (IDL) is the analyte concentration that is required to produce a signal greater than three times the standard deviation of the noise level.
Inductively coupled plasma mass spectrometry (ICP-MS) is a type of mass spectrometry that uses an inductively coupled plasma to ionize the sample. It atomizes the sample and creates atomic and small polyatomic ions, which are then detected.
Fig. 2. The construction of Inductively Coupled Plasma torch. [3] A: cooling gas tangential flow to the outer quartz tube B: discharge gas flow (usually Ar) C: flow of carrier gas with sample D: induction coil which forms the strong magnetic field inside the torch E: force vectors of the magnetic field F: the plasma torch (the discharge).
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
Sector instruments tend to surpass the TQMS in mass resolution and mass range. [3] However, the triple quadrupole has the advantage of being cheaper, easy to operate and highly efficient. [3] Also, when operated in the selected reaction monitoring mode, the TQMS has superior detection sensitivity as well as quantification. [3]
Like liquid chromatography–mass spectrometry, it allows analysis and detection even of tiny amounts of a substance. [2] GC–MS has been regarded as a "gold standard" for forensic substance identification because it is used to perform a 100% specific test, which positively identifies the presence of a particular substance. A nonspecific test ...
I suggest that Detection limit and Detection Limits be merged. Biscuittin 18:32, 5 July 2007 (UTC) []. Support Added templates. --Kkmurray 14:51, 19 August 2007 (UTC) []While the initial definition on the Detection Limits entry seems OK, most of the information appears to be related to the amount of material being probed, rather than a description of what a detection limit (or detection limits ...