Search results
Results from the WOW.Com Content Network
For example, such a regulation might limit the concentration of NOx to 55 ppmv in a dry combustion exhaust gas corrected to 3 volume percent O 2. As another example, a regulation might limit the concentration of particulate matter to 0.1 grain per standard cubic foot (i.e., scf) of dry exhaust gas corrected to 12 volume percent CO 2.
The powder is placed inside a pycnometer of known volume, and weighed. The pycnometer is then filled with a fluid of known density, in which the powder is not soluble. The volume of the powder is determined by the difference between the volume as shown by the pycnometer, and the volume of liquid added (i.e. the volume of air displaced).
The system can be traced back to the measuring systems of the Hindus [18]: B-9 and the ancient Egyptians, who subdivided the hekat (about 4.8 litres) into parts of 1 ⁄ 2, 1 ⁄ 4, 1 ⁄ 8, 1 ⁄ 16, 1 ⁄ 32, and 1 ⁄ 64 (1 ro, or mouthful, or about 14.5 ml), [19] and the hin similarly down to 1 ⁄ 32 (1 ro) using hieratic notation, [20] as ...
Gas expansion pycnometer is also known as constant volume gas pycnometer. The simplest type of gas pycnometer (due to its relative lack of moving parts) consists of two chambers, one (with a removable gas-tight lid) to hold the sample and a second chamber of fixed, known (via calibration) internal volume – referred to as the reference volume or added volume.
In US customary units, most units of volume exist both in a dry and a liquid version, with the same name, but different values: the dry hogshead, dry barrel, dry gallon, dry quart, dry pint, etc. The bushel and the peck are only used for dry goods. Imperial units of volume are the same for both dry and liquid goods. They have a different value ...
= 10 parts per million by volume = 10 ppmv = 10 volumes/10 6 volumes NO x molar mass = 46 kg/kmol = 46 g/mol Flow rate of flue gas = 20 cubic metres per minute = 20 m 3 /min The flue gas exits the furnace at 0 °C temperature and 101.325 kPa absolute pressure. The molar volume of a gas at 0 °C temperature and 101.325 kPa is 22.414 m 3 /kmol.
The density of quartz is around 2.65 g/cm 3 but the (dry) bulk density of a mineral soil is normally about half that density, between 1.0 and 1.6 g/cm 3. In contrast, soils rich in soil organic carbon and some friable clays tend to have lower bulk densities ( <1.0 g/cm 3 ) due to a combination of the low-density of the organic materials ...
It is calibrated to deliver accurately a fixed volume of liquid. These pipettes have a large bulb with a long narrow portion above with a single graduation mark as it is calibrated for a single volume (like a volumetric flask). Typical volumes are 1, 2, 5, 10, 20, 25, 50 and 100 mL.