A generator interlock kit (or a transfer switch), eliminates the need for extension cords to power appliances. [2]Like a transfer switch, an interlock kit lets the generator energize the panel and all of its circuits (up to the load capacity of the generator); not just corded appliances.
An ELCB is a specialised type of latching relay that has a building's incoming mains power connected through its switching contacts so that the ELCB disconnects the power when earth leakage is detected. The ELCB detects fault currents between line and earth (ground) conductors within the portion of the installation it protects.
A stepping relay is a specialized kind of multi-way latching relay designed for early automatic telephone exchanges. An earth-leakage circuit breaker includes a specialized latching relay. [clarification needed] Very early computers often stored bits in a magnetically latching relay, such as ferreed or the later remreed in the 1ESS switch.
A latching switch is a switch that maintains its state after being activated. [1] A push-to-make, push-to-break switch would therefore be a latching switch – each time you actuate it, whichever state the switch is left in will persist until the switch is actuated again. [2]
AC contactor for pump application. A contactor is an electrically controlled switch used for switching an electrical power circuit. [1] A contactor is typically controlled by a circuit which has a much lower power level than the switched circuit, such as a 24-volt coil electromagnet controlling a 230-volt motor switch.
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
Such a "reed pack" was able to store one decimal digit, encoded in a two-out-of-five code (74210 code variant) for easy validity checking by wire spring relay logic. Such an electrically latching reed relay requires continuous power to maintain state, unlike magnetically latching relays, such as ferreed (ferrite and reed relay) or the later ...
Synchroscopes or lamps are sometimes installed as a supplement to automatic relays, for possible manual use or for monitoring the generating unit. Sometimes as a precaution against out-of-step connection of a machine to a system, a "synchro check" relay is installed that prevents closing the generator circuit breaker unless the machine is ...