enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Useful conversions and formulas for air dispersion modeling

    en.wikipedia.org/wiki/Useful_conversions_and...

    For example, such a regulation might limit the concentration of NOx to 55 ppmv in a dry combustion exhaust gas corrected to 3 volume percent O 2. As another example, a regulation might limit the concentration of particulate matter to 0.1 grain per standard cubic foot (i.e., scf) of dry exhaust gas corrected to 12 volume percent CO 2.

  3. Total dissolved solids - Wikipedia

    en.wikipedia.org/wiki/Total_dissolved_solids

    14] Water can be classified by the level of total dissolved solids (TDS) in the water: Fresh water: TDS is less than 1,000 ppm. Brackish water: TDS = 1,000 to 10,000 ppm. Saline water: TDS = 10,000 to 35,000 ppm. Hypersaline: TDS greater than 35,000 ppm. Drinking water generally has a TDS below 500 ppm.

  4. Total suspended solids - Wikipedia

    en.wikipedia.org/wiki/Total_suspended_solids

    TSS of a water or wastewater sample is determined by pouring a carefully measured volume of water (typically one litre; but less if the particulate density is high, or as much as two or three litres for very clean water) through a pre-weighed filter of a specified pore size, then weighing the filter again after the drying process that removes all water on the filter.

  5. CT Value - Wikipedia

    en.wikipedia.org/wiki/CT_Value

    In water treatment practice, tables of the product C×t are used to calculate disinfection dosages. The calculated CT value is the product of the disinfectant residual (in mg/L) and the detention time (in minutes), through the section at peak hourly flow. [ 5 ]

  6. Air pollutant concentrations - Wikipedia

    en.wikipedia.org/wiki/Air_pollutant_concentrations

    As an example, a measured NO x concentration of 45 ppmv in a dry gas having 5 volume % O 2 is: 45 × ( 20.9 - 3 ) ÷ ( 20.9 - 5 ) = 50.7 ppmv of NO x. when corrected to a dry gas having a specified reference O 2 content of 3 volume %. Note: The measured gas concentration C m must first be corrected to a dry basis before using the above equation.

  7. Dilution (equation) - Wikipedia

    en.wikipedia.org/wiki/Dilution_(equation)

    V = air or gas volume of the closed space or room in cubic feet, cubic metres or litres; Q = ventilation rate into or out of the room in cubic feet per minute, cubic metres per hour or litres per second; C initial = initial concentration of a vapor inside the room measured in ppm; C final = final reduced concentration of the vapor inside the ...

  8. Moisture analysis - Wikipedia

    en.wikipedia.org/wiki/Moisture_analysis

    Moisture content measurements can be reported in multiple units, such as: parts per million, pounds of water per million standard cubic feet of gas, mass of water vapor per unit volume or mass of water vapor per unit mass of dry gas.

  9. Template:Table composition of dry atmosphere - Wikipedia

    en.wikipedia.org/wiki/Template:Table_composition...

    Composition of dry atmosphere, by volume [ note 1 ... Trace to 30 ppm ... 100.00% 1,000,080 100.00% Not included in above dry atmosphere: Water vapor: