Search results
Results from the WOW.Com Content Network
Or, if wired for two-line service (rare), a second ring wire is carried on pin 2 for line 2, with the outer pair, pins 1 and 6 carrying the second line. This arrangement was introduced for the same reason as the capacitor in BS 6313; to allow backwards compatibility with older GPO style type 3 wire phones that lacked an anti-tinkle circuit ...
For example, telephone cables in the UK typically have a BS 6312 (UK standard) plug at the wall end and a 6P4C or 6P2C modular connector at the telephone end: this latter may be wired as per the RJ11 standard (with pins 3 and 4), or it may be wired with pins 2 and 5, as a straight-through cable from the BT plug (which uses pins 2 and 5 for the ...
Only lines 1 and 2 have electrical compatibility, with T568A wiring, and only line 1 with T568B wiring, because Ethernet-compatible pin assignments split the third pair of RJ25 across two separate cable pairs, rendering that pair unusable by an analog phone. (With T568B wiring, a telephone may connect to line 3 as line 2.) Both the third and ...
When used for plain old telephone service (POTS), the first wire is known as the tip or A-leg (U.K.) conductor, and is usually connected to the positive side of a direct current (DC) circuit, while the second wire is known as the ring lead or B-leg (U.K.), and is connected to the negative side of the circuit. Neither of these two sides of the ...
An automotive wiring diagram, showing useful information such as crimp connection locations and wire colors. These details may not be so easily found on a more schematic drawing. A wiring diagram is a simplified conventional pictorial representation of an electrical circuit. It shows the components of the circuit as simplified shapes, and the ...
Ethernet cable with an M12 X-coded connector in one end and a modular connector in the other. IEC metric screw sized connectors is a family of electrical connectors defined by IEC that are named according to their ISO metric screw thread , namely M5 , M8 and M12 . [ 1 ]
A cable terminated according to T568A on one end and T568B on the other is a crossover cable when used with the earlier twisted-pair Ethernet standards that use only two of the pairs because the pairs used happen to be pairs 2 and 3, the same pairs on which T568A and T568B differ. Crossover cables are occasionally needed for 10BASE-T and ...
(IET Wiring Regulations), currently in its 18th edition, which provide the detailed descriptions referred to by legislation. UK electrical wiring standards are largely harmonised with the regulations in other European countries and the international IEC 60446 standard. However, there are a number of specific national practices, habits and ...