Search results
Results from the WOW.Com Content Network
The service factor is typically in the 1.15-1.4 range, with the figure being lower for higher-power motors. For every hour of operation at the service-factor-adjusted power rating, a motor loses two to three hours of life at nominal power, i.e. its service life is reduced to less than half for continued operation at this level.
A common size for cells inside cordless tool battery packs. This size is also used in radio-controlled scale vehicle battery packs and some Soviet multimeters. 1 ⁄ 2-, 4 ⁄ 5 - and 5 ⁄ 4-sub-C sizes (differing in length) are also available. Soviet 332 type can be replaced with R10 (#4, 927, BF, U8) or 1.5 V elements from 3 V 2xLR10 packs ...
Cell chemistry Also known as Electrode Rechargeable Commercialized Voltage Energy density Specific power Cost † Discharge efficiency Self-discharge rate
For example, if a battery comprises four identical cells connected in parallel and delivers a current of 1 ampere, the current supplied by each cell will be 0.25 ampere. If the cells are not identical in voltage, cells with higher voltages will attempt to charge those with lower ones, potentially damaging them.
As an example, the 5-15R is the common 125 V two-pole, three-wire receptacle rated for 15 A. The L5-15R, while sharing the same electrical rating, is a locking design that is not physically compatible with the straight-blade 5-15 design. The 5-30R has the same two-pole, three-wire configuration and 125 V rating, but is rated for 30 A.
In Europe, electricity is normally distributed for industry and domestic use by the three-phase, four wire system. This gives a phase-to-phase voltage of 400 volts wye service and a single-phase voltage of 230 volts between any one phase and neutral. In the UK a typical urban or suburban low-voltage substation would normally be rated between ...
Series II current ratings are 20, 30, 60, 100, 200, 300, 350, 500 and 600 amps. The voltage ratings go up to 1000 V AC. These have been replacing the American-style for some time and are much more likely to be found in food processing, data centers, healthcare, entertainment, and other industries.
Types used in commercial and industrial low-voltage distribution systems are rated to safely interrupt 200,000 amperes. The rating of power circuit breakers varies according to the application voltage; a circuit breaker that interrupts 50,000 amperes at 208 volts might be rated to interrupt only 10,000 amperes at 600 volts, for example.