enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Fire blocking - Wikipedia

    en.wikipedia.org/wiki/Fire_blocking

    Fire blocking or firestopping terminology was used interchangeably in code language from its first mention in the 1905 National Building Code (NBC), and requirements were expanded in the 1927 Uniform Building Code (UBC). Building code terminology settled on different definitions of the terms by 2000. [4]

  3. Firestop - Wikipedia

    en.wikipedia.org/wiki/Firestop

    A firestop or fire-stopping is a form of passive fire protection that is used to seal around openings and between joints in a fire-resistance-rated wall or floor assembly. Firestops are designed to maintain the fire-resistance rating of a wall or floor assembly intended to impede the spread of fire and smoke.

  4. Penetrant (mechanical, electrical, or structural) - Wikipedia

    en.wikipedia.org/wiki/Penetrant_(mechanical...

    Building codes require a firestop to seal the openings around penetrants. Electrical cable through-penetration, fire-stopped by an intumescent sealant, to restore the two-hour fire-resistance rating of the concrete floor.

  5. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    Fire-resistance rated wall assembly with fire door, cable tray penetration and intumescent cable coating. Passive fire protection (PFP) is components or systems of a building or structure that slows or impedes the spread of the effects of fire or smoke without system activation, and usually without movement. [1]

  6. Joint (building) - Wikipedia

    en.wikipedia.org/wiki/Joint_(building)

    A building joint is a junction where building elements meet without applying a static load from one element to another. When one or more of these vertical or horizontal elements that meet are required by the local building code to have a fire-resistance rating, the resulting opening that makes up the joint must be firestopped in order to restore the required compartmentalisation.

  7. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    The Deactivation and Decommissioning (D&D) customized extension of the electrical code standard defined by National Electrical Code was developed since current engineering standards and code requirements do not adequately address the unique situations arising during D&D activities at U.S. Department of Energy (DOE) facilities. The additional ...

  8. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    A firestop mortar is applied around the penetrations. The completed test sample is inserted into a furnace such that one side is exposed to a fire. The test is terminated when the fire stops successfully meet the test criteria in minimizing the amount of heat and smoke allowed to pass through the assembly, when the fire penetrates the fire stops.

  9. Building code - Wikipedia

    en.wikipedia.org/wiki/Building_code

    Requirements for earthquake (seismic code), hurricane, flood, and tsunami resistance, especially in disaster prone areas or for very large buildings where a failure would be catastrophic [citation needed] Requirements for specific building uses (for example, storage of flammable substances, or housing a large number of people)