Search results

  1. Results from the WOW.Com Content Network
  2. Voltage regulation - Wikipedia

    en.wikipedia.org/wiki/Voltage_regulation

    In the voltage regulation formula, V no load is the voltage measured at the receiving end terminals when the receiving end is an open circuit. The entire short line model is an open circuit in this condition, and no current flows in an open circuit, so I = 0 A and the voltage drop across the line given by Ohm’s law V line drop = IZ line is 0 ...

  3. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    The open-circuit test, or no-load test, is one of the methods used in electrical engineering to determine the no-load impedance in the excitation branch of a transformer. The no load is represented by the open circuit, which is represented on the right side of the figure as the "hole" or incomplete part of the circuit.

  4. Load regulation - Wikipedia

    en.wikipedia.org/wiki/Load_regulation

    is the voltage at maximum load. The maximum load is the one that draws the greatest current, i.e. the lowest specified load resistance (never short circuit); is the voltage at minimum load. The minimum load is the one that draws the least current, i.e. the highest specified load resistance (possibly open circuit for some types of linear ...

  5. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    An important property of three-phase power is that the instantaneous power available to a resistive load, = =, is constant at all times.Indeed, let = = To simplify the mathematics, we define a nondimensionalized power for intermediate calculations, =

  6. Performance and modelling of AC transmission - Wikipedia

    en.wikipedia.org/wiki/Performance_and_modelling...

    In electrical engineering, the Ferranti effect is the increase in voltage occurring at the receiving end of a very long (> 200 km) AC electric power transmission line, relative to the voltage at the sending end, when the load is very small, or no load is connected. It can be stated as a factor, or as a percent increase:.

  7. No-load loss - Wikipedia

    en.wikipedia.org/wiki/No-load_loss

    No-load loss (also called "fixed loss") is a portion of the loss of electricity that does not depend on the power being distributed through an electric circuit, as opposed to the load loss. [1] No-load loss typically depends on the operating voltage of a grid unit [2] and can be attributed to: dielectric loss in cables; [3]

  8. Power-flow study - Wikipedia

    en.wikipedia.org/wiki/Power-flow_study

    In power engineering, the power-flow study, or load-flow study, is a numerical analysis of the flow of electric power in an interconnected system. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system, and focuses on various aspects of AC power parameters, such as Voltage, voltage angles, real power and reactive power.

  9. Line regulation - Wikipedia

    en.wikipedia.org/wiki/Line_regulation

    The unit here is %/V. For example, In the ABLIC Inc. S1206-series regulator device the typical line regulation is expressed as 0.05%/V which means that the change in the output with respect to change in the input of the regulator device is 0.05%, when the output of the device is set at 1V.