enow.com Web Search

  1. Ads

    related to: 2 hour exterior wall

Search results

  1. Results from the WOW.Com Content Network
  2. Firewall (construction) - Wikipedia

    en.wikipedia.org/wiki/Firewall_(construction)

    A fire barrier wall, or a fire partition, is a fire-rated wall assembly that are not structurally self-sufficient. [ 2 ] Fire barrier walls are typically continuous from an exterior wall to an exterior wall, or from a floor below to a floor or roof above, or from one fire barrier wall to another fire barrier wall, having a fire resistance ...

  3. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    This is the rating required to protect microfilm, microfiche, and other film-based information storage media. Above 150 °F (65.5 °C) film is distorted by the heat and information is lost. A Class 150-2 Hour vault must keep the temperature below 150 °F. for at least two hours, with temperatures up to 2,000 °F. (1,093.3 °C) outside the vault.

  4. Firestop - Wikipedia

    en.wikipedia.org/wiki/Firestop

    They receive a fire rating by combining materials in an arrangement specific to the item (a pipe or cable, for example) penetrating the fire-rated wall or floor and the construction arrangement of the fire-rated wall or floor. A two-hour-rated pipe-penetration firestop may consist of a layer of caulking over packed mineral wool. The arrangement ...

  5. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    Fire-resistance rated wall assembly with fire door, cable tray penetration and intumescent cable coating. Passive fire protection (PFP) is components or systems of a building or structure that slows or impedes the spread of the effects of fire or smoke without system activation, and usually without movement. [1]

  6. Curtain wall (architecture) - Wikipedia

    en.wikipedia.org/wiki/Curtain_wall_(architecture)

    A curtain wall is an exterior covering of a building in which the outer walls are non-structural, instead serving to protect the interior of the building from the elements. Because the curtain wall façade carries no structural load beyond its own dead load weight, it can be made of lightweight materials.

  7. High-voltage transformer fire barriers - Wikipedia

    en.wikipedia.org/wiki/High-voltage_transformer...

    The primary North American document that deals with outdoor high-voltage transformer fire barriers is NFPA 850. [1] NFPA 850 outlines that outdoor oil-insulated transformers should be separated from adjacent structures and from each other by firewalls, spatial separation, or other approved means for the purpose of limiting the damage and potential spread of fire from a transformer failure.

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Framing (construction) - Wikipedia

    en.wikipedia.org/wiki/Framing_(construction)

    Interior loadbearing walls are framed in the same way as exterior walls. Studs are usually 1 + 1 ⁄ 2 in × 3 + 1 ⁄ 2 in (38 mm × 89 mm) lumber spaced at 16 in (410 mm) on center. This spacing may be changed to 12 or 24 in (300 or 610 mm) depending on the loads supported and the type and thickness of the wall finish used. [12]

  1. Ads

    related to: 2 hour exterior wall