enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    The "local" Earth/Ground electrode provides "system grounding" [13] at each building where it is installed. The "Grounded" current carrying conductor is the system "neutral". Australian and New Zealand standards use a modified protective multiple earthing (PME [ 14 ] ) system called multiple earthed neutral (MEN).

  3. Ground continuity monitor - Wikipedia

    en.wikipedia.org/wiki/Ground_continuity_monitor

    A GCM or ground continuity monitor (also called a ground integrity monitor or ground continuity tester) is an electrical safety device that monitors the impedance to ground of a temporary electrical circuit and can provide indication (or protective trip) in the event impedance rises to an unsafe value. A GCM is either an external testing device ...

  4. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    Permanently installed electrical equipment, unless not required to, has permanently connected grounding conductors. Portable electrical devices with metal cases may have them connected to earth ground by a pin on the attachment plug (see AC power plugs and sockets). The size of power grounding conductors is usually regulated by local or ...

  5. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  6. Shaft voltage - Wikipedia

    en.wikipedia.org/wiki/Shaft_voltage

    Currents due to shaft voltage causes deterioration of motor bearings, but can be prevented with a grounding brush on the shaft, grounding of the motor frame, insulation of the bearing supports, or shielding. Shaft voltage can be induced by non-symmetrical magnetic fields of the motor (or generator) itself.

  7. Backfeeding - Wikipedia

    en.wikipedia.org/wiki/Backfeeding

    A common source of unintentional backfeeding is an electrical generator (typically a portable generator) that is improperly connected to a building electrical system.A properly installed electrical generator incorporates the use of a transfer switch or generator interlock kit to ensure the incoming electrical service line is disconnected when the generator is providing power to the building.

  8. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    The ground loop still exists, but the two sides of the loop are close together, so stray magnetic fields induce equal currents in both sides, which cancel out. Break in the shield Create a break in the signal cable shield conductor. [5] The break should be at the load end. This is often called ground lifting. It is the simplest solution; it ...

  9. Isolated ground - Wikipedia

    en.wikipedia.org/wiki/Isolated_ground

    An isolated ground (IG) (or Functional Earth (FE) in European literature) is a ground connection to a local earth electrode from equipment where the main supply uses a different earthing arrangement, one of the common earthing arrangements used with domestic mains supplies.